- 32 -
6 Troubleshooting
6.1 LCD Display Messages (continued)
Jammed Strap Removal
1.
Open Upper Table Front Assembly M7-5-210020
2.
Lift up the Lever A (M7-2-101400/M7-2-101410) with left hand and take out the Cover B
(M7-1-311220) for the Upper Guide with right hand at the same time.
3.
Take out the jammed strap and cut it.
4.
Put the cover (M7-1-311220) for the Upper Guide back to its position and put the Upper Table
Front Assembly back as well. Push START switch in the control panel to RESTART machine.
If the Feed jam problem still cannot be solved, the following causes have to be checked as well:
Fault
Cause
Remedy
Feed Jam
Strap too curved
Change strap
Insufficient feeding pressure
Adjust feeding pressure
Too much strap in the
accumulator box and has
caused strap to curve
Adjust strap accumulator strap
amount
4. Other Malfunctions
Fault
Cause
Remedy
Sealing Failure
Too much debris on sides of the
heater plate
Clean both sides of the heater
plate with fine sandpaper
Insufficient heater temperature Increase heater temperature
Insufficient cooling time
Insufficient Strap Tension
Soft-High tension switch is at
“soft” position
Change tension switch to “high”
position
Lubricant drops into tension
roller
Clean the lubricant
Too much debris in the gear of
the tension roller
Clean the debris
A