- 15 -
3. Machine Setup & Installation
3.6 Operating Elements (Continued)
Function Description
0
The photo-eye is disabled. The strapping cycle must be
initiated with Start switch on the control panel, Foot bar
switch or optional foot pedal.
1
A single strapping cycle: initiates a
cycle when a package is detected by the photo-eye. Delay
time for initiating the cycle is controlled by TIMER 1.
N
Multiple strapping cycles: initiates a
cycle when a package is detected by the photo-eye.
Cycling continuously until the photo-eye is no longer
“detects” a package. The cycle timing is determined by
TIMER 1 and TIMER 2.
Timer 1 Sets the delay time from the moment that a package is
detected until the first
strapping cycle initiates. This
allows an operator to properly position a package for the
first strap. It is adjustable from zero to five seconds.
Timer 2 It’s the delay time (interval) between strap cycles. When
multiple strapping cycles are needed, this timer is for an
operator to determine the interval between each straps. It
is adjustable from zero to five seconds.
11. Foot Bar (Rear) (option)- Used to initiate a strapping cycle or to clear a
machine fault (reset).
1
7
8
10
9
7.
Reel Release Switch – Used to release the dispenser
for removal.
8.
Foot Bar (Front) – Used to initiate a strapping cycle or
to clear a machine fault (reset).
9.
Foot Pedal Switch (option) – Used to initiate a
strapping cycle or clear a machine fault (reset).
10.
Photo Eye Switch (option) – Used to automatically
initiate strapping cycle when a package is detected.