24
X9 Swing Rev - H
SINGLE Gate Progr
amming
PROG
Pres
s
M1
Pres
s
P/P
Pres
s
P/P
M1
Program Travel Distance and Pause Time to Close Gate(s)
SINGLE Gate Programming
1
ON
2 3 4 5 6 7
PROG
P3
P/P
TR1
LD1
BSC
BSA
FT1
FT2
J1
J2
STP
1
2
3
4
5
6
7
8
Rall.
9
O
N
2 M.
11
O
N
Almost full
open position
Start Pause
Hold down the
PROG
button for at least 3 seconds until led
LD1
lights up.
“Programming mode”
has been activated.
Press the
P/P
button. The gate should begin to
CLOSE
, if it opens instead,
shut-off the power
,
reverse
motor M1
Red and Black wires and start again.
When gate has
closed
it will
stop
and start
opening automatically
.
When the gate has
opened completely
(reaching the mechanical stop),
PAUSE TIME
memorization will start
automatically
.
NOTE:
If automatic reclosing pause is not desired you may
press
P/P
button
immediately
.
Once the desired
PAUSE TIME
has elapsed,
Press P/P button
.
Gate will begin to
close
.
Shut-off the power.
Manually release
the operator and move to an
almost fully open
position. Re-lock operator and turn power back
ON
.
LD1
M1
M1
M1
M1
6
9
3
12
Stop Pause
End Program
6
9
3
12
M1
LD1
Turns OFF
Limit switches and mechanical stops
MUST
be
CORRECTLY
positioned
BEFORE
programming either
SINGLE
or
BI-PARTING
gates on next page.
NOTE:
If the operator stops
before reaching the travel
limit,
decrease
the
TR1
reversing
sensitivity
adjustment (clockwise).
Closed
DIP-Switch 9 set to
ON
only
AFTER
programming complete. The
OPTIONAL
programmed slow down times
will be
enabled
.
BEFORE
beginning programming, check the correct DIP-Switch settings and connections by observing the leds:
OPTIONAL
Slow Down
programming: Not required to complete programming. Typically used with uneven opening, longer or heavier gates.
PROGRAMMING & ADJUSTMENTS
DIP-Switch 11-2 M
OFF
for
SINGLE
Gate.
DIP-Switch 11-2 M
ON
for
Bi-Parting
Gates.
DIP-Switch 9-Rall.
ON
DURING
programming:
Self-learning
cycle that
slows down
after
5 SEC
so it can find the mechanical travel limit
safely
.
Use this setting for longer and/or heavier gate.
DIP-Switch 9-Rall.
OFF
DURING
programming:
Rapid
mechanical
travel limit detection
without
slow down.
BSC
C
PED STP P/P
C
12 13
11
10
9
8
7
6
5
4
3
2
1
SC
ST
BSC
C
J1
J2 PC PA PED STP P/P
C
12 13
11
10
9
8
7
6
5
4
3
2
1
SC
J1
J2
ST
BSC, BSA, FT1, FT2, J1, J2 and STP
MUST
be
LIT
BSC, BSA, FT1, FT2, J1, J2, PC, PA and STP
MUST
be
LIT
SINGLE
Gate
Bi-Parting
Gates
When the gate has
closed completely
, the motor will stop, led
LD1
will
turn OFF
and programming
mode ends.
Pulling the 4 Amp fuse
will shut-off power.
ON / OFF
Summary of Contents for X9L
Page 2: ...2 X9 Swing Rev H...
Page 33: ...31 X9 Slide Rev H...