X9 Swing Rev - H

Photo Ey

e

Sensing Edge

1

2

5

6

8

9

12

13

7

10 11

3

4

14

COM

24 COM

+

+

+

24VDC

MAG LOCK

MOTOR

2 LIMITS

MOTOR

1 LIMITS

OPEN EXIT

MOTOR

COM

REVERSE

LOOP

5

4

3

2

1

10 11

9

8

7

6

14

13

12

Photo Eye OPENING Direction

Used with the 13-Pin Terminal - Entrapment Protection

Sensing Edge Installation and Wiring

Open Gate

Opening

Direction

Opening

Direction

Closing
Direction

Entrapment Area

5” or less

Open Gate

21”

Typical

No 

higher 

than 

27.5”

Top View

Side View

Open Gate

Sensing Edges

Top View

Side View

Install along 

entire edge of 

gate.

Mount the edges in position shown and run wires to control box in conduit.

Mount photo eye in position shown and run wire to control box in conduit.

8K2 Required

wired in series

LEDs light up when sensors are activated.

24 VDC - #8

24 Com - #10

Opening
Direc

tion

1

ON

2 3

4

5 6 7

BSC

BSA

FT1

FT2

J1

J2

STP

BSC

C

BSA FT1

J1

J2 PC PA PED STP P/P

C

FT2

12 13

11

10

9

8

7

6

5

4

3

2

1

BSC

C

BSA FT1

J1

J2 PC PA PED STP P/P

C

FT2

12 13

11

10

9

8

7

6

5

4

3

2

1

SW 4 

OFF

13-Pin Terminal

13-Pin Terminal

1

ON

2 3 4 5 6 7

BSC

BSA

FT1

FT2

J1

J2

STP

SW 1 

OFF

1

ON

2

3 4 5 6 7

BSC

BSA

FT1

FT2

J1

J2

STP

SW 2 

OFF

SW 4 

ON

Separate Power

OR

 24 VDC Power

From Control Board

Closing

Direction

NC

NC

Com

Com

Com

Photo Eye

NC

Open Gate

FT2

h

BSC BSA

SA

ADVANCED ACCESSORY CONNECTION

ON

DIP

1 2 3

4

5

LED lights up when sensor is activated.

Opening
Direction

FT2

1

ON

2345678

9

10
11
12

1

ON

2 3 4 5 6 7

+

-

24V

FT

+

-

LAMP.

+

-

EL. LOCK

+

-

+

-

+

-

+

-

+

-

NO

D

ENCODER

D

M1

NC

C

+

-

24V
SPIA

24V

SPIA 2

F16A

F3A

PRG-LINK

PROG

OC2 RECEIVER

P2

P1

STOP

Reset

TA

ST3F

P3

US1

P/P

P/P

J

BSC

C

SEC TR

BSA FT1

J1

J2 PC PA PED STP P/P

C

TR1

LD1

FT2

Prel.
Rich
US1
C.Sg
Rall.
C.Ch
2 M.
Fot.R

BSC

BSA

FT1

FT2

J1

J2

STP

FU

S

E

FU

S

E

FU

S

E

FU

S

E

+

-

24V

ANTENNA

M2

M2

M1

12

11

10

9

8

7

6

5

4

3

2

1

12

13

11

10

9

8

7

6

5

4

3

2

1

3

2

1

5

4

3

2

1

5

4

3

2

1

Summary of Contents for X9L

Page 1: ...wing Gate Operators X9S X9L X9S X9L TM ACCESS CONTROL SYSTEMS INC BY EA GLE ACCES S CONTR OL SY ST EM S INC X9L Long Arm X9S Short Arm Gate Capacity 10 ft 700 lbs Gate Capacity 16 ft 800 lbs Installat...

Page 2: ...2 X9 Swing Rev H...

Page 3: ...ifications Swing Gate Recommendations Important Safety Information General Safety Information 2 3 4 5 5 2 PROGRAMMING ADJUSTMENTS Program Travel Distance and Pause Time to Close Gate s SINGLE Gate Pro...

Page 4: ...ted from reaching over under around or through the gate to operate the controls Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use 7 The Stop and or Reset...

Page 5: ...SS IV Restricted Access Vehicular Gate Operator A vehicular gate operator opener or system intended for use in a guarded industrial location or buildings such as airport security area or other restric...

Page 6: ...avel of the vehicular gate Gates Closed Separate Pedestrian Access Opening Gates should have smooth bottom edges with vertical bottom edged protrusions not exceeding 0 50 inches If distance is greater...

Page 7: ...ate Be sure to mount ALL gate operating devices at least six feet 6 away from any moving part of the gate They must NOT be able to be operated reaching through the gate Injuries may be avoided if a me...

Page 8: ...the electronic components making up the single gate installation Dual gates setup is on the next page These drawings do not lay down any requirements regarding the installation of the gate operator Pl...

Page 9: ...ces get wired to the control box in conduit when possible BY EAGLE ACCESS CONTRO L SYSTEM S INC Opening Direction Photocell Opening Direction Photocell Inside Property Phantom Loop Shadow Master Slave...

Page 10: ...open door 2 Flip orange handle forward 3 Stroke pin can now be moved 4 To Lock Stroke Pin again Flip orange handle back to original position 5 Close and lock door NOTE The stroke pin can REMAIN UNLOCK...

Page 11: ...Stroke Pin Min Max X9L Long Arm X9S Short Arm Max Stroke 4 Minimum Above Ground 2 2 Offset Between Brackets 18 3 4 19 5 8 18 3 4 38 1 2 32 1 2 4 13 3 4 3 3 4 Rear Front NOTE Weld COMPLETELY around br...

Page 12: ...with appropriate hardware not included Mounting Hole 7 1 2 Mounting Hole Mount the control box as near as possible to the actuator arm Keep the box high enough above the ground to avoid landscape spr...

Page 13: ...establishes the maximum opening angle and the length of the actuator s linear stroke The longer the stroke the greater the torque and smoother movements of the gate The shorter the stroke the less th...

Page 14: ...he brackets establishes the maximum opening angle and the length of the actuator s linear stroke The longer the stroke the greater the torque and smoother movements of the gate The shorter the stroke...

Page 15: ...ft 14 AWG 600 ft 12 AWG 1200 ft 10 AWG 2000 ft 8 AWG 300 ft 500 ft 1000 ft 1700 ft Single Arm Dual Arms 120 VAC 120 VAC Input Power Wire 120 VAC Input Power Wire Runs Maximums SEC L T4A 120V 120V 50...

Page 16: ...nd Mounting Bracket Max Sensing Range 49 ft 15m Outdoors Beam is aligned with reflector when yellow ALIGN LED turns ON Sensing Range Adjustment Turning Clockwise Range becomes longer Turning Counter C...

Page 17: ...al power up If operator begins to close shut off power and reverse Red and Black wires Supplied Photo Eye should be installed in closing direction as shown see page 17 for installation requirements DI...

Page 18: ...Photo Eye M1 Power M1 Limits Green Gray Blue Black M1 1 Red M1 2 MOTOR 1 Inputs 1 2 3 OPEN OUTSIDE SINGLE OPERATOR PHOTO EYE WIRING DIP Switch Settings 1 ON 2 3 4 5 6 7 8 9 10 11 12 P P J Prel Rich US...

Page 19: ...M2 Power Closing Direction Photo Eye Open INSIDE M1 Open INSIDE M2 Green Gray Blue Red M1 1 Black M1 2 MOTOR 1 Inputs 1 2 3 Green Gray Blue MOTOR 2 Inputs 1 5 4 Red M2 1 Black M2 2 DIP Switch Setting...

Page 20: ...M2 Power Red Gray Green Gray Blue Blue Blue Black White Green Gray Blue Black M1 1 Red M1 2 MOTOR 1 Inputs 1 2 3 Green Gray Blue MOTOR 2 Inputs 1 5 4 Black M2 1 Red M2 2 OPEN OUTSIDE DUAL OPERATORS PH...

Page 21: ...IP Switch 5 for desired Operation OFF The flashing light ONLY operates when motor operates ON The flashing light operates 5 seconds before any motor operation During opening closing operations activat...

Page 22: ...5 6 7 BSC BSA FT1 FT2 J1 J2 STP BSC C BSA FT1 J1 J2 PC PA PED STP P P C FT2 12 13 11 10 9 8 7 6 5 4 3 2 1 BSC C BSA FT1 J1 J2 PC PA PED STP P P C FT2 12 13 11 10 9 8 7 6 5 4 3 2 1 SW 4 OFF 13 Pin Term...

Page 23: ...hree times Fill the grooves with a proper sealant Connect loop feed wires directly to external loop detector Loop feed must have the loop wires twisted in them approximately 6 twists per foot When gat...

Page 24: ...minal 5 FT2 must remain disconnected J1 5 Device has been installed on terminals 6 J1 Excludes the J1 input on terminals 6 J1 NOTE Terminals 6 J1 must remain disconnected J2 6 Device has been installe...

Page 25: ...e stopped using electric travel limits Use N C contacts Dual Operators OFF OFF J1 Timer J2 FT 3 J1 FCA M1 J2 FCC M1 J1 FCA M1 J2 FCA M2 J1 FCA M1 J2 FCC M1 PA FCA M2 PC FCC M2 3 ON 4 OFF ON 3 ON 4 ON...

Page 26: ...RRECTLY positioned BEFORE programming either SINGLE or BI PARTING gates on next page NOTE If the operator stops before reaching the travel limit decrease the TR1 reversing sensitivity adjustment clock...

Page 27: ...amming mode ends When the gate with M2 Operator has opened completely reaching the mechanical stop PAUSE TIME memorization will start automatically NOTE If automatic reclosing is not being used you ma...

Page 28: ...30 remotes Optional EG652 receiver has a maximum capacity of 300 remotes Receiver Program Button Remote Button Green wire not used LED Radio Receiver Eagle Part Number EG650 Remote 1 ON 2 3 4 5 6 7 8...

Page 29: ...ge to the moving part of the gate When adjusting the sensors sensitivity TOO sensitive If the gate stops or reverses by itself NOT sensitive enough If the gate strikes an object and does NOT stop or r...

Page 30: ...STP P P C TR1 LD1 FT2 Prel Rich US1 C Sg Rall C Ch 2 M Fot R BSC BSA FT1 FT2 J1 J2 STP F U S E F U S E F U S E F U S E 24V ANTENNA M2 M2 M1 12 11 10 9 8 7 6 5 4 3 2 1 12 13 11 10 9 8 7 6 5 4 3 2 1 3...

Page 31: ...4 COM 24 COM 24VDC MAG LOCK MOTOR 2 LIMITS MOTOR 1 LIMITS OPEN EXIT MOTOR COM REVERSE LOOP 5 4 3 2 1 10 11 9 8 7 6 14 13 12 Moving Gate Can Cause Serious Injury or Death KEEP CLEAR Gate may move at an...

Page 32: ...ing Sign Dual Operator Kit X9002 X9004 X9006 X9008 X9010 X9012 X9014 X9016 X9018 X9020 X9022 X9024 X9026 X9028 X9030 X9032 X9034 X9035 X9 Number Part Description If you are uncertain about a specific...

Page 33: ...31 X9 Slide Rev H...

Page 34: ...53 Foothill Blvd Sylmar Ca 91342 Copyright 2018 Eagle Access Control systems Inc All rights reserved Toll Free 1 800 708 8848 Phone 818 837 7900 Fax 818 837 7911 www eagleoperators com TM ACCESS CONTR...

Reviews: