-
4 0
-
-
41
-
F u n c t i o n C o d e T a b l e
EC6000
F u n c t i o n C o d e T a b l e
EC6000
0.1~6500.0S
PA
-
30
Dormant base
duration
30.0s
0A1EH
0.1~6500.0S
PA
-
31
Enter dormant
deceleration
time
60.0s
0A1FH
0.00~20.00Hz
PA
-
32
Sleep low holding
frequency
10.00Hz
0A20H
0.0~6500.0S
PA
-
33
Low frequency
operation time
10.0s
0A21H
0.0~100.0%
PA
-
34
Wake-up base
50.0%
0A23H
0.0~6500.0S
PA
-
35
Wake-up base
duration
30.0s
0A24H
PB
Communication control function parameters
PB
-
00
PB
-
01
PB
-
02
Function
Code
Master-slave
selection
Address
Baud rate
selection
Parameter Name
Master-slave selection 0:Slave 1:Master
1
~
247
0:1200bps 1:2400bps
2:4800bps 3:9600bps
4:19200bps 5:38400bps
6: 57600bps 7: 115200bps
Setting Range
0
1
3
Default
0B00H
0B01H
0B02H
Address
PB
-
03
Data format
3
0B03H
PB
-
04
PB
-
05
PB
-
06
PB
-
07
Communication
proportion
setting
Communication
response delay
Communication
timeout
failure time
Transmission
response
processing
0: (N,8,1)No check,data format:8, stop bit:1
1: (E,8,1)Even parity check,data format:8,
stop bit:1
2: (0,8,1)Odd Parity check,data format:8,
stop bit:1
3: (N,8,2)No check,data format:8, stop bit:2
4: (E,8,2)Even parity check,data format:8,
stop bit:2
5: (0,8,2)Odd Parity check,data format:8,
stop bit:2
0.000
~
5.000
0
~
0.500s
0.0
~
100.0s
0: Write response
1: Write no response
1.000
0.000s
1.0s
0
0B04H
0B05H
0B06H
0B08H
PB
-
08
Master send
selection
BIT0: The first set of transmission frame
selection
0: Invalid
1: Run command setting
2: Master set frequency
0031
0B09H
3: Master output frequency
4: Master upper limit frequency
5: Master set torque (reserved)
6: Master output torque
7: Limit of forward speed of master torque
control (reserved)
8: Limit of reserved speed of master torque
control (reserved)
9: PID set by the mater
A:master feedback PID
BIT1: Second set of transmission frame
selection Ditto
BIT2: The third set of transmission frame
selection
Ditto
BIT3: Selection of the fourth set of trans-
mission frames
Ditto
PB
-
08
Master send
selection
0031
0B09H
Address
0C00H
0C01H
Default
000
12.00Hz
Function
Code
PC
-
00
PC
-
01
P C
Op ti mi za ti o n Pa r ame t ers
Setting Range
BIT0: 0:Temperature independent
1:Temperature related
BIT1: 0:Asynchronous modulation
1: Synchronous modulation
BIT2:0: Random PWM invalid
1-A:Random PWM
BIT3:Reserved
0
~
15.00Hz
Parameter Name
Carrier frequency
characteristic
selection
DPWM switchover
frequency
upper limit
0C08H
0C02H
0C03H
0C04H
0C05H
0C06H
0C07H
350V
0
1
1
690V
100%
810.0V
PC
-
08
PC
-
02
PC
-
03
PC
-
04
PC
-
05
PC
-
06
PC
-
07
200.0
~
2000.0V
0: The operation of the fan isjust related to
the temperature
1
~
A: The operation is related to the tempera-
ture, and during run, the
fan is operating.
Fixed air volume, maximum air volume above
fifth gear
0
~
1
0
~
2
200
~
2000.0V
0
~
100%
0
~
2500.0V
Undervoltage
threshold
Cooling fan
control
Rapid current
limit enable
Dead zone
compensation mode
Dynamic braking
turn-on voltage
Action voltage of
energy consumption
braking
Overvoltage
threshold