AVIIVA® EM1
24
1043D - AVIIVA EM1 –04/11
e2v semiconductors SAS 2011
6.3.1
How to Read the Tables of Parameters below?
Format / Color hierarchy in the Parameter Tables
Standard Parameters :
They use the following Font of Characters :
GevDeviceModeCharacterSet
Type
: IInteger, IBoolean, ICommand, IString, IFloat …
Specific Type : IEnumeration
GevCCP
OpenAccess
ExclusiveAccess
=> List of Possible values
ControlAccess
Access
: R = Read Only, R/W = Read/Write
Visibility
: B=Beginner, E=Expert, G=Guru
Selection Parameters :
The value set in this Parameter (or the selection in the List) decides for a new branch of Parameters.
The Font of Characters used is the same as
standard
but
underlined
. The new branch of parameters
which depends from this value is listed after and the Font of Characters is in
Blue
. Then the “Blue”
Parameter attribution depends on the underlined parameter setting
Example with the Gain settings :
Two parameters :
Are equivalent to the Seven following Parameters :
GainSelector
AnalogAll
Gain
= “AnalogAll Gain Value” (Preamp Gain setting)
All
Gain
= “All Gain Value” (Amp Gain setting)
DigitalTap1
Gain
= “DigitalTap1 Gain Value” (Gain Tap1 setting)
DigitalTap2
Gain
= “DigitalTap2 Gain Value” (Gain Tap2 setting)
DigitalTap3
Gain
= “DigitalTap3 Gain Value” (Gain Tap3 setting)
DigitalTap4
Gain
= “DigitalTap4 Gain Value” (Gain Tap4 setting)
DigitalAll
Gain
= “DigitalAll Gain Value” (Digital Gain setting)
Gain
The contextual parameters (in
Blue
) can have all the same type of the standard ones (IInteger …)