AVIIVA® EM1
60
1043D - AVIIVA EM1 –04/11
e2v semiconductors SAS 2011
6.3.14
SaveRestoreSettings
The settings (or Main configuration) of
the Camera can be saved in 4 different
User banks and one Integrator bank.
This setting includes also the FFC and
LUT enable parameters
Name
Interface
Lock Access
Visibility
Description
UserSetSelector
User1
User2
User3
User4
Integrator
IEnumeration
L R/W
B
Selects the feature User Set to load
or save.
UserSetSave
ICommand
L (R)/W
B
Save the User Set specified by
UserSetSelector to the non-volatile
memory of the device.
UserSetLoad
ICommand
L (R)/W
B
Loads the User Set specified by
UserSetSelector to the device and
makes it active.
CurrentUserSet
IInteger
- R
B
Indicated the last User Set memory
Saved/loaded
The integrator bank (5) can be written only if the Camera is set in integrator mode (Privilege level
= 1). This integrator bank can be used as a « Factory default » by a system integrator.