Series (In line) device; 

 

resistor – SxxxR 

 

diode – SD1 

 

zener – SxxxZ 

 

LED  

 

 

 

Fig 8a -PT Version Push Action 

 
To reset, insert the reset tool supplied with the unit into the 2-
off  holes  in  the  button  plate,  rotate  clockwise  along  the 
curved  slots  and  then  pull  the  button  plate  back  up.  Rotate 
the tool anti clockwise and remove through the 2-off holes in 
the button plate. 
 

13) End-of-Line and Series Devices 

 

All  models  can  be  fitted  with  series  resistors,  end-of-line 
monitoring  resistors,  monitoring  diodes  and  zener  diodes  if 
supplied  with  direct  current  up  to  48Vdc  and  limited  to  a 
maximum total power consumption no greater than 6.224W. 
 
Min. resistor values and current limitations must be observed 
depending on supply voltage and type of components fitted. If 
a  combination  of  resistors  /  diodes  /  zener  diodes  is  used, 
values  for  all  components  must  be  observed  and  lowest 
current limit for either component becomes overall limit. 
 
Current  limitation  for  units  fitted  with  end-of-line  resistors, 
diodes  or  zener  diodes  must  be  ensured  by  using  a  current 
limited power supply or fitting a current limiting resistor at the 
control panel (not provided). 
 
The  following  table  1  shows  limitations  for  all  possible 
variations: 
 
 

 
Note: - The maximum voltage stated must not be exceeded, 
as  the  internal  resistor  modules  are  rated  as  compliant  with 
Ex d according to the unit voltage. 
 
If lower value resistors than seen on table are required it may 
be possible to configure but seek advice from E2S to ensure 
compliance is still maintained. 
 
EOL (End of line) device; 

 

 

resistor – ExxxR 

 

 

diode – ED1 

 

 

zener – ExxxZ 

 

 
 

  

Microswitch 1 = M/S 1 
Microswitch 2 = M/S 2 
 
The unit can be wired with a maximum of 4 module devices – 
see wiring schematic D202-06-211 
When  customer  is  fitting  EOL  or  Series  devices,  ensure 
device  leads  are  insulated  or  routed  so  as  not  to  create  an 
electrical short. 

 

14) Maintenance, Overhaul & Repair 

 

Maintenance,  repair  and  overhaul  of  the  equipment  should 
only  be  carried  out  by  suitably  qualified  personnel  in 
accordance with the current relevant standards: 

 

EN60079-19/IEC60079-19 

Explosive 

atmospheres 

Equipment repair, overhaul and reclamation 
 
EN60079-17/IEC60079-17 

Explosive 

atmospheres 

Electrical installations inspection and maintenance 

 

 
To  avoid  a  possible  ELECTROSTACTIC  CHARGE  the  unit 
must only be cleaned with a damp cloth. 

 

Units must  not  be  opened  while an  explosive  atmosphere  is 
present. 
 

 

Supply voltage 24Vdc 

Supply voltage 48Vdc 

Type of 
component 
fitted 

value 

Max. current 

(mA) 

value 

Max. 

current 

(mA) 

End-of-Line 
Resistor 
*See note 

min. 470R/ 
2W or min. 
2k2/ 0.5W 

3000 

min. 2k2/ 
2W or 
min. 8k2/ 
0.5W 

1000 

End-of-Line 
Diode 
Type 
1N5401 

2W 

59.13  

2W 

25.26 

Series 
Resistor 
*See note 

min. 470R/ 
2W or min. 
2k2/ 0.5W 

3000 

min. 2k2/ 
2W or 
min. 8k2/ 
0.5W 

1000 

Series 
Diode 
Type 
1N5401 

2W 

59.13 

2W 

25.26  

Series 
Zener 
Diode Type 
1N5333B 

3.3V 

230  

3.3V 

230  

4.7V 

162  

4.7V 

162  

5.1V 

149  

5.1V 

149  

5.6V 

136  

5.6V 

136  

6.2V 

122  

6.2V 

122  

6.8V 

112  

6.8V 

112  

10V 

76  

10V 

76  

12V 

63  

12V 

63  

Summary of Contents for GNExCP7-PB-D

Page 1: ...s Electromechanical contactors and motorstarters Ed 2 Issue Date 2014 01 04 The GNExCP7 callpoints are rated as follows Class I Div 2 Group ABCD T6 Ta 55 C to 60 C Class II Div 2 Group FG T4 Ta 55 C t...

Page 2: ...it will only exist for a short time Dust Groupings Group IIIA Combustible Flyings Group IIIB Non conductive Dust Group IIIC Conductive Dust Maximum Surface Temperature for Dust Applications ATEx IECE...

Page 3: ...re between the two castings is secure and the O ring seal is in place When fitting the flameproof cover ensure the cover is sitting flat and correctly positioned on the base Insert the M6 x 50 stainle...

Page 4: ...Ex UKEX certified adapters 10 Cable Connections Electrical Connections are to be made into the terminal blocks using solid or stranded wire See section 6 of this manual for access to the flameproof en...

Page 5: ...y twisted by 90 degrees clockwise to position shown and then pressed in There will be a click sound to indicate positive engagement and the plunger will stay in place Fig 6 PB Version Twist and Push A...

Page 6: ...ximum voltage stated must not be exceeded as the internal resistor modules are rated as compliant with Ex d according to the unit voltage If lower value resistors than seen on table are required it ma...

Page 7: ...idered suitable for use in low demand safety function Random Hardware Failures and Systematic Failures route 2H As an unvoted item i e hardware fault tolerance of 0 at SIL 2 The product was assessed a...

Page 8: ...as shown in Operated condition Terminals 4 5 7 8 closed Terminals 4 5 6 open COM N O N C EOL SER NOTE These can be fitted either by customer or pre installed by E2S at point of order When fitting diod...

Page 9: ...1 2 3 4 5 6 7 8 COM N O N C COM N O N C COM N O N C COM N O N C Standard Unit showing positions of optional Series and EOL Devices 1 2 3 4 5 6 M S 1 M S 2 7 8 N O COM 4A Circuit as shown in Unoperate...

Page 10: ...in Unoperated condition Terminals 1 4 M S 1 and 5 8 M S 2 open Terminals 1 3 M S 1 and 5 7 M S 2 closed N C N O COM N C 1 2 3 4 5 6 M S 1 M S 2 7 8 N O COM EOL 4B Circuit as shown in Operated conditi...

Page 11: ...S 1 M S 2 R B Y R B Y R B Y R B Y 5B Circuit as shown in Operated condition Terminals 1 2 M S 1 and 4 5 M S 2 open Terminals 1 3 M S 1 and 4 6 M S 2 closed R N POTTS Optional Single or Double Microswi...

Page 12: ...uipment II 2G Ex d IIC T6 T5 Gb II 2D Ex tb IIIC T90 C T80 C Db Standards applied EN 60079 0 2018 EN 60079 1 2014 EN 60079 31 2014 IP6X Dust Protection to EN60079 0 EN60079 31 Directive 2014 30 EU Ele...

Page 13: ...d IIC T6 T5 Gb II 2D Ex tb IIIC T90 C T80 C Db Standards applied EN 60079 0 2018 EN 60079 1 2014 EN 60079 31 2014 IP6X Dust Protection to EN60079 0 EN60079 31 Directive 2014 30 EU Electromagnetic Comp...