European Safety Systems Ltd.
Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880
Document No. D202-00-211-IS Issue 5 16-12-2022 Sheet 2 of 7
All units have a rating label, which carries the following
important information: -
Model No.:
GNExCP7-PB-S (Single Switch)
GNExCP7-PB-D (Dual Switch)
GNExCP7-PM-S (Single Switch)
GNExCP7-PM-D (Dual Switch)
GNExCP7-PT-S (Single Switch)
GNExCP7-PT-D (Dual Switch)
Input Voltage:
24Vdc max / 3.0A max
48Vdc max / 1.0A max
250Vac max / 5.0A max (units without
series or end-of-line devices only)
Ex db IIC T5 Gb Ta. -55 to +70°C
Ex db IIC T6 Gb Ta. -55 to +60°C
Ex tb IIIC T90°C Db Ta. -55° to +70°C
Certificate No.
DEMKO 19 ATEX 2101X
IECEx ULD 19.0007X
UL21UKEX2134X
UKCA Marking
Notified Body No.
The units can be installed in locations with the following
conditions:
Area Classification Gas:
Zone 1
Explosive gas air mixture likely to occur in
normal operation.
Zone 2
Explosive gas atmosphere not likely to
occur in normal operation but may be
present for short periods.
Gas Groupings:
Group IIA
Propane
Group IIB
Ethylene
Group IIC
Hydrogen and Acetylene
Temperature Classification:
T1
450ºC
T2
300ºC
T3
200ºC
T4
135ºC
T5
100ºC
T6
85ºC (only up to Tamb 60°C)
Area Classification Dust:
Zone 21
Explosive dust air mixture likely to occur in
normal operation.
Zone 22
Explosive dust air mixture not likely to
occur in normal operation, and if it does, it
will only exist for a short time.
Dust Groupings:
Group IIIA
Combustible Flyings
Group IIIB
Non-conductive Dust
Group IIIC
Conductive Dust
Maximum Surface Temperature for Dust Applications:
ATEx/IECEx/UKEX:
90ºC
NEC/CEC:
125°C
IP Rating:
IP66/67 to EN/IEC60529 and IP6X to
EN/IEC60079-0, EN/IEC60079-31
Equipment Category:
2G / 2D
Equipment Protection Level:
Gb, Gc, Db, Dc
Ambient Temperature Range:
ATEX/IECEx/UKEX:
55ºC to +70ºC
NEC/CEC:
55ºC to +60ºC
Pollution Degree: 3
3) Installation Requirements
The unit must only be installed by suitably qualified personnel
in accordance with the latest issues of the relevant standards:
EN60079-14 / IEC60079-14: Explosive atmospheres - Electrical
installations design, selection and erection
EN60079-10-1 / IEC60079-10-1: Explosive atmospheres -
Classification of areas. Explosive gas atmospheres
The installation of the units must also be in accordance with
any local codes that may apply and should only be carried
out by a competent electrical engineer who has the
necessary training.
The equipment must not be installed with any obstruction to
the flanged flameproof joint any closer than permitted as per
EN/IEC60079-14, table 13.
4) Special Conditions of Use
The stainless steel button is not earthed and may generate
an ignition-capable level of electrostatic charges. It has a max
capacitance of 6.33pF according to EN/IEC60079-0, clause
7.5.
Equipment is permitted to be wall mounted only in vertical
position. The enclosure base is permitted in two mounting
positions, with the double entry lowermost or uppermost.
No repair to the Flamepaths is permitted
Flame Path on Base shown
hatched
2813
II 2G
II 2D
CE Marking
Notified Body No.
ATEX Marking
Equipment Group and
Category:
0518