background image

 
 
 
 
 
 

 
 
 
 
 
 
 
 

E2S

 

Telephone:

 

+44

 

(0)20

 

8743

 

8880

 

Fax:

 

+44

 

(0)20

 

8740

 

4200

 

Email:

 

[email protected]

 

www.e2s.com

 

DC

078_Issue_E

 ‐ 

Page

 

1

 

of

 

1

 ‐ 

QAF_252_Issue_5

 

 
 
 

Martin

 

Streetz

 

Document

 

No.:

 

DC

078_Issue_E

 

Quality

 

Assurance

 

Manager

 

Date

 

and

 

Place

 

of

 

Issue:

 

London,

 

23/12/2020

 

EU

 

Declaration

 

of

 

Conformity

 

Manufacturer:

   

 

European

 

Safety

 

Systems

 

Ltd.

 

 

 

 

Impress

 

House,

 

Mansell

 

Road,

 

Acton

 

 

 

 

London,

 

W3

 

7QH

 

 

 

 

United

 

Kingdom

 

 

Authorised

 

Representative:

 

E2S

 

Warnsignaltechnik

 

UG

 

 

 

 

Charlottenstrasse

 

45

51

 

 

 

 

72764

 

Reutlingen

 

 

 

 

Germany

 

 

Equipment

 

Type:

 

GNExCP7

BG,

 

GNExCP7

PB,

 

GNExCP7

PM,

 

GNExCP7

PT

 

 

Directive

 

2014/34/EU:

 

Equipment

 

and

 

Protective

 

Systems

 

for

 

use

 

in

 

Potentially

 

Explosive

 

Atmospheres

 

(ATEX)

 

Notified

 

Body

 

for

 

EU

 

type

 

Examination

 

(Module

 

B):

 

UL

 

International

 

Demko

 

A/S

 

Notified

 

Body

 

No.:

 

0539

 

Borupvang

 

5A,

 

2750

 

Ballerup,

 

Denmark

 

EU

type

 

Examination

 

Certificate

 

(Module

 

B):

 

DEMKO

 

19

 

ATEX

 

2101X

 

Notified

 

Body

 

for

 

Quality

 

Assurance

 

Notification

 

/

 

Conformity

 

to

 

EU

type

 

based

 

on

 

quality

 

assurance

 

of

 

the

 

production

 

process

 

(Module

 

D):

 

Sira

 

Certification

 

Service

 

Notified

 

Body

 

No.:

 

2813

  

CSA

 

Group

 

Netherlands

 

B.V,

 

Utrechtseweg

 

310,

 

6812

 

AR,

 

Arnhem,

 

Netherlands

 

Quality

 

Assurance

 

Notification

 

(Module

 

D):

 

SIRA

 

05

 

ATEX

 

M342

 

Provisions

 

fulfilled

 

by

 

the

 

equipment:

 

II

 

2G

 

Ex

 

d

 

IIC

 

T6…T5

 

Gb

 

II

 

2D

 

Ex

 

tb

 

IIIC

 

T90°C….T80°C

 

Db

 

Standards

 

applied:

 

EN

 

60079

0:2018

 

EN

 

60079

1:2014

 

EN

 

60079

31:2014

 

IP6X

 

Dust

 

Protection

 

to

 

EN60079

0

 

/

 

EN60079

31

 

Directive

 

2014/30/EU:

 

Electromagnetic

 

Compatibility

 

Directive

 

(EMC)

  

Standards

 

applied:

 

EN

 

61000

6

1:2007

 

EN

 

61000

6

2:2005

 

EN

 

61000

6

3:2007

 

/

 

A1:2011

 

/

 

AC:

 

2012

 

EN

 

61000

6

4:2007

 

/

 

A1:

 

2011

 

Directive

 

2011/65/EU:

 

Restriction

 

of

 

the

 

use

 

of

 

certain

 

hazardous

 

substances

 

in

 

electrical

 

and

 

electronic

 

equipment

 

(RoHS)

 

The

 

product

 

and

 

all

 

the

 

components

 

contained

 

within

 

it

 

are

 

in

 

accordance

 

with

 

the

 

restriction

 

of

 

the

 

use

 

of

 

hazardous

 

substances

 

in

 

electrical

 

and

 

electronic

 

equipment,

 

including

 

amendment

 

by

 

Directive

 

2015/863/EU.

 

Regulation

 

(EC)

 

1907/2006:

 

Registration,

 

Evaluation,

 

Authorisation

 

and

 

Restriction

 

of

 

Chemicals

 

(REACH)

 

The

 

product

 

and

 

all

 

the

 

components

 

contained

 

within

 

it

 

are

 

free

 

from

 

substances

 

of

 

very

 

high

 

concern.

 

Other

 

Standards

 

and

 

Regulations

 

EN

 

60529:1991

 

+

 

A1:2000

 

+

 

A2:2013.

 ‐ 

Degrees

 

of

 

protection

 

provided

 

by

 

enclosures

 

(IP

 

code)

 

 

enclosure

 

rated

 

IP66/67

 

 

On

 

behalf

 

of

 

European

 

Safety

 

Systems

 

Ltd.,

 

I

 

declare

 

that,

 

on

 

the

 

date

 

the

 

equipment

 

accompanied

 

by

 

this

 

declaration

 

is

 

placed

 

on

 

the

 

market,

 

the

 

equipment

 

conforms

 

with

 

all

 

technical

 

and

 

regulatory

 

requirements

 

of

 

the

 

above

 

listed

 

directives,

 

regulations

 

and

 

standards.

 

 

This

 

Declaration

 

is

 

issued

 

under

 

the

 

sole

 

responsibility

 

of

 

the

 

manufacturer.

 

Summary of Contents for GNExCP7-PB-D

Page 1: ...s Electromechanical contactors and motorstarters Ed 2 Issue Date 2014 01 04 The GNExCP7 callpoints are rated as follows Class I Div 2 Group ABCD T6 Ta 55 C to 60 C Class II Div 2 Group FG T4 Ta 55 C t...

Page 2: ...it will only exist for a short time Dust Groupings Group IIIA Combustible Flyings Group IIIB Non conductive Dust Group IIIC Conductive Dust Maximum Surface Temperature for Dust Applications ATEx IECE...

Page 3: ...re between the two castings is secure and the O ring seal is in place When fitting the flameproof cover ensure the cover is sitting flat and correctly positioned on the base Insert the M6 x 50 stainle...

Page 4: ...Ex UKEX certified adapters 10 Cable Connections Electrical Connections are to be made into the terminal blocks using solid or stranded wire See section 6 of this manual for access to the flameproof en...

Page 5: ...y twisted by 90 degrees clockwise to position shown and then pressed in There will be a click sound to indicate positive engagement and the plunger will stay in place Fig 6 PB Version Twist and Push A...

Page 6: ...ximum voltage stated must not be exceeded as the internal resistor modules are rated as compliant with Ex d according to the unit voltage If lower value resistors than seen on table are required it ma...

Page 7: ...idered suitable for use in low demand safety function Random Hardware Failures and Systematic Failures route 2H As an unvoted item i e hardware fault tolerance of 0 at SIL 2 The product was assessed a...

Page 8: ...as shown in Operated condition Terminals 4 5 7 8 closed Terminals 4 5 6 open COM N O N C EOL SER NOTE These can be fitted either by customer or pre installed by E2S at point of order When fitting diod...

Page 9: ...1 2 3 4 5 6 7 8 COM N O N C COM N O N C COM N O N C COM N O N C Standard Unit showing positions of optional Series and EOL Devices 1 2 3 4 5 6 M S 1 M S 2 7 8 N O COM 4A Circuit as shown in Unoperate...

Page 10: ...in Unoperated condition Terminals 1 4 M S 1 and 5 8 M S 2 open Terminals 1 3 M S 1 and 5 7 M S 2 closed N C N O COM N C 1 2 3 4 5 6 M S 1 M S 2 7 8 N O COM EOL 4B Circuit as shown in Operated conditi...

Page 11: ...S 1 M S 2 R B Y R B Y R B Y R B Y 5B Circuit as shown in Operated condition Terminals 1 2 M S 1 and 4 5 M S 2 open Terminals 1 3 M S 1 and 4 6 M S 2 closed R N POTTS Optional Single or Double Microswi...

Page 12: ...uipment II 2G Ex d IIC T6 T5 Gb II 2D Ex tb IIIC T90 C T80 C Db Standards applied EN 60079 0 2018 EN 60079 1 2014 EN 60079 31 2014 IP6X Dust Protection to EN60079 0 EN60079 31 Directive 2014 30 EU Ele...

Page 13: ...d IIC T6 T5 Gb II 2D Ex tb IIIC T90 C T80 C Db Standards applied EN 60079 0 2018 EN 60079 1 2014 EN 60079 31 2014 IP6X Dust Protection to EN60079 0 EN60079 31 Directive 2014 30 EU Electromagnetic Comp...

Reviews: