E2S GNExCP7-PB-D Instruction Manual Download Page 13

 

 

 

 

 

 
 

 

 
 

 
E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: [email protected] 

www.e2s.com 

DC-099_Issue_A - Page 1 of 1 - QAF_252_Issue_5

 

 

 

 

Martin Streetz 

Document No.: 

DC-099_Issue_A 

Quality Assurance Manager 

Date and Place of Issue: 

London, 24/02/2022 

UKCA Declaration of Conformity 

Manufacturer:   

 

European Safety Systems Ltd. 

 

 

 

Impress House, Mansell Road, Acton 

 

 

 

London, W3 7QH 

 

 

 

United Kingdom 

 

Equipment Type: GNExCP7-BG, GNExCP7-PB, GNExCP7-PM, GNExCP7-PT 

 

Directive  UKSI 2016:1107 (as amended by UKSI 2019:696) – Schedule 3A, Part 1 : Product or Protective System Intended for use in Potentially Explosive Atmospheres  
(UKCA) 

 
Notified Body for UK type Examination (Module B): 

UL International (UK) Ltd 
Notified Body No.: 0843 

Unit 1-3 Horizon Kingsland Business Park, Wade Road, 

Basingstoke, Hampshire RG24 8AH UK 

UK-type Examination Certificate (Module B): 

UL21UKEX2134X 

Notified Body for Quality Assurance Notification / Conformity to EU-type 

based on quality assurance of the production process (Module D): 

Sira Certification Service 

Notified Body No.: 0518 
Rake Lane, Eccleston, Chester CH4 9JN, UK 

Quality Assurance Notification (Module D): 

CSAE 22UKQAN0046 

Provisions fulfilled by the equipment: 

II 2G Ex d IIC T6…T5 Gb 

II 2D Ex tb IIIC T90°C… T80°C Db 

Standards applied: 

EN 60079-0:2018 

EN 60079-1:2014 
EN 60079-31:2014 

IP6X Dust Protection to EN60079-0 / EN60079-31 

Directive 2014/30/EU: Electromagnetic Compatibility Directive (EMC)  

Standards applied: 

EN 61000-6-1:2007 
EN 61000-6-2:2005 

EN 61000-6-3:2007 / A1:2011 / AC: 2012 

EN 61000-6-4:2007 / A1: 2011 

Directive 2011/65/EU: Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) 
The product and all the components contained within it are in accordance with the restriction of the use of hazardous substances in electrical and electronic 
equipment, including amendment by Directive 2015/863/EU.

 

Regulation (EC) 1907/2006: Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) 

The product and all the components contained within it are free from substances of very high concern. 

Other Standards and Regulations 

EN 60529:1991 + A1:2000 + A2:2013. - Degrees of protection provided by enclosures (IP code) – enclosure rated IP66/67 

 

On behalf of European Safety Systems Ltd., I declare that, on the date the equipment accompanied by this declaration is placed on the market, the equipment 
conforms with all technical and regulatory requirements of the above listed directives, regulations and standards. 

 
This Declaration is issued under the sole responsibility of the manufacturer.

 

Summary of Contents for GNExCP7-PB-D

Page 1: ...s Electromechanical contactors and motorstarters Ed 2 Issue Date 2014 01 04 The GNExCP7 callpoints are rated as follows Class I Div 2 Group ABCD T6 Ta 55 C to 60 C Class II Div 2 Group FG T4 Ta 55 C t...

Page 2: ...it will only exist for a short time Dust Groupings Group IIIA Combustible Flyings Group IIIB Non conductive Dust Group IIIC Conductive Dust Maximum Surface Temperature for Dust Applications ATEx IECE...

Page 3: ...re between the two castings is secure and the O ring seal is in place When fitting the flameproof cover ensure the cover is sitting flat and correctly positioned on the base Insert the M6 x 50 stainle...

Page 4: ...Ex UKEX certified adapters 10 Cable Connections Electrical Connections are to be made into the terminal blocks using solid or stranded wire See section 6 of this manual for access to the flameproof en...

Page 5: ...y twisted by 90 degrees clockwise to position shown and then pressed in There will be a click sound to indicate positive engagement and the plunger will stay in place Fig 6 PB Version Twist and Push A...

Page 6: ...ximum voltage stated must not be exceeded as the internal resistor modules are rated as compliant with Ex d according to the unit voltage If lower value resistors than seen on table are required it ma...

Page 7: ...idered suitable for use in low demand safety function Random Hardware Failures and Systematic Failures route 2H As an unvoted item i e hardware fault tolerance of 0 at SIL 2 The product was assessed a...

Page 8: ...as shown in Operated condition Terminals 4 5 7 8 closed Terminals 4 5 6 open COM N O N C EOL SER NOTE These can be fitted either by customer or pre installed by E2S at point of order When fitting diod...

Page 9: ...1 2 3 4 5 6 7 8 COM N O N C COM N O N C COM N O N C COM N O N C Standard Unit showing positions of optional Series and EOL Devices 1 2 3 4 5 6 M S 1 M S 2 7 8 N O COM 4A Circuit as shown in Unoperate...

Page 10: ...in Unoperated condition Terminals 1 4 M S 1 and 5 8 M S 2 open Terminals 1 3 M S 1 and 5 7 M S 2 closed N C N O COM N C 1 2 3 4 5 6 M S 1 M S 2 7 8 N O COM EOL 4B Circuit as shown in Operated conditi...

Page 11: ...S 1 M S 2 R B Y R B Y R B Y R B Y 5B Circuit as shown in Operated condition Terminals 1 2 M S 1 and 4 5 M S 2 open Terminals 1 3 M S 1 and 4 6 M S 2 closed R N POTTS Optional Single or Double Microswi...

Page 12: ...uipment II 2G Ex d IIC T6 T5 Gb II 2D Ex tb IIIC T90 C T80 C Db Standards applied EN 60079 0 2018 EN 60079 1 2014 EN 60079 31 2014 IP6X Dust Protection to EN60079 0 EN60079 31 Directive 2014 30 EU Ele...

Page 13: ...d IIC T6 T5 Gb II 2D Ex tb IIIC T90 C T80 C Db Standards applied EN 60079 0 2018 EN 60079 1 2014 EN 60079 31 2014 IP6X Dust Protection to EN60079 0 EN60079 31 Directive 2014 30 EU Electromagnetic Comp...