35
PGN 65287 – Proprietary B
Transmission Rate:
as requested by the user or in the event of value change, max. 100 ms
Data Length:
8 bytes
Data page:
0
PDU format
255
PDU Specific:
7
Default Priority:
6
Parameter Group Number: 65287 (FF07h)
CAN-ID 0x18FF07xx
xx Node address SCS200
Overview set-up CAN data
CAN data
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Contents
Analog input 5
Analog input 6
not used
not used
not used
not used
Unit
10 mV
10 mV
–
–
–
–
Byte
Bit
Description
Value
Byte 3
Analog input 2
LSB analog input 2
Byte 4
MSB analog input 2
Byte 5
Analog input 3
LSB analog input 3
Byte 6
MSB analog input 3
Byte 7
Analog input 4
LSB analog input 4
Byte 8
MSB analog input 4
Byte
Bit
Description
Value
Byte 1
Analog input 5
LSB analog input 1
Byte 2
MSB analog input 1
Byte 3
Analog input 6
LSB analog input 2
Byte 4
MSB analog input 2
Byte 5
not used
0x00
Byte 6
not used
0x00
Byte 7
not used
0x00
Byte 8
not used
0x00
7.4.4.3 Voltage values per channel
The measured voltage levels are sent by the SCS200 within three different CAN messages as listed in the following:
The messages are sent as a response to the corresponding transmission request and upon change of the corresponding voltage
value. Low voltage levels are screened out to avoid unnecessary load of the bus.