31
CAN data
Example
Query switching status of channels.
Node-ID SCS200: 0xA0
Source address of sender: 0x64
7.4.3.3 Activate sleep mode
In order to put a single SCS200 module into sleep mode, the following CAN message must be used.
PGN 61184 – Proprietary A
Transmission Rate:
N/A (only Rx)
Data Length:
8 bytes
Data page:
0
PDU format
239
PDU Specific:
Destination Address (SCS200 node address)
Default Priority:
6
Parameter Group Number: 61184 (EF00h)
CAN-ID 0x18EFxxyy
xx Node address SCS200
yy: optional source address of sender
Overview set-up CAN data
Byte
Bit
Description
Value
Byte 1
bits 8 – 5
message ID status and diagnosis
0x3
bits 4 – 1
manufacturer ID part 1
0x3
Byte 2
manufacturer ID part 2
0xD8
Byte 3
Activate sleep mode
0x01
Byte 4
not used
0x00
Byte 5
not used
0x00
Byte 6
not used
0x00
Byte 7
not used
0x00
Byte 8
not used
0x00
CAN-ID
CAN data
0x18EFA064
0x33 0xD8 0x05 0x00 0x00 0x00 0x00 0x00
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Contents
Message ID and
manufacturer ID
Manufacturer ID
requirement
not used
not used
not used
not used
not used
Unit
–
–
–
–
–
–
–
–
In order to put all SCS200 modules on the bus simultaneously into sleep mode, the following Proprietary B broadcast message
must be used.