The SCS200 responds to the particular request with Proprietary B messages (PGNs 65286 and 65287, also see 7.4.4.2).
7.4.3.2.2 Query total current, U
Bat
and module temperature
CAN data
The SCS200 responds to the particular request with Proprietary B messages (PGN 65285, also see 7.4.4.1).
7.4.3.2.3 Query status conditions and diagnostic data
CAN data
Byte
Bit
Description
Value
Byte 1
bits 8 – 5
message ID General measuring value query
0x2
bits 4 – 1
manufacturer ID part 1
0x3
Byte 2
manufacturer ID part 2
0xD8
Byte 3
query total current, U
Bat
and module temperature
0x02
Byte 4
not used
0x00
Byte 5
not used
0x00
Byte 6
not used
0x00
Byte 7
not used
0x00
Byte 8
not used
0x00
Byte
Bit
Description
Value
Byte 1
bits 8 – 5
message ID status and diagnosis
0x3
bits 4 – 1
manufacturer ID part 1
0x3
Byte 2
manufacturer ID part 2
0xD8
Byte 3
query status condition and diagnostic data
0x03…0x05
Byte 4
not used
0x00
Byte 5
not used
0x00
Byte 6
not used
0x00
Byte 7
not used
0x00
Byte 8
not used
0x00
Coding the diagnostic query within the CAN message
0x03
query load status and error diagnosis
0x04
reset error diagnosis bits
0x05
query switching status of channels
The SCS200 responds to the particular request with Proprietary B messages (PGNs 65294 and 65295, also see 7.4.4.5 and 7.4.4.6).
If an error was detected by the module, the diagnosis bits must be reset or acknowledged by sending the corresponding
CAN message after remedy of the failure.
Byte
Bit
Description
Value
Byte 7
not used
0x00
Byte 8
not used
0x00