MAINTE       NANCE

Before undertaking any maintenance, ensure that your

 

 

is disconnected from supply.  If operations are to be undertaken after 

using

 

, you must wait until the fan in the applicator has completely shut down before disconnecting the base unit from supply.  

This will also ensure that the optical components are correctly cooled.

NOTE:

 

Unlike the fans in the applicator, which will shut down after a certain time, the fans in the base unit will continue to run until the 

device is finally disconnected from supply.

 BASE

 

PLASTIC COMPONENTS

Do not clean the interior of the dedicated slot for the activation 

card.   All plastic components of the device must be cleaned using a 

clean cloth which has been moistened in water (with no additional 

products).

TOUCHSCREEN

The screen must be cleaned using a clean cloth, impregnated with 

the 

clean

 spray (never apply the 

clean

 spray directly to the 

touch screen).

MAINS LEAD

Check that the lead is in perfect condition (not trapped or 

compressed, with no wires exposed). Clean the lead using a cloth 

which has been moistened in water (with no additional products).

 APPLICATOR

MOBILE HEAD

Cleaning the internal optical components of the mobile head 

using the 

clean

 spray before and after each use will ensure 

the maintenance of the effective operation of your device. Never 

apply the 

clean

 spray directly to the internal components of the 

applicator. 

APPLICATOR BODY

All plastic components of the applicator must be cleaned using a 

clean cloth which has been moistened in water (with no additional 

products). 

 APPLICATOR CABLE

This cable must be kept clean at all times, and must be free of 

any visible deterioration. Any excessive bending or compression 

of the cable must be avoided.  In case of any doubt regarding the 

 

condition of this cable, it is absolutely essential that you should 

discontinue the operation of your device.

  VENTILATION SLOTS IN THE BASE UNIT 

AND APPLICATOR

The  applicator  and  the  base  unit  are  ventilated.  Grilles  are 

incorporated into both the applicator and the base unit, at the 

bottom and on the rear at the top. You must ensure that all 

grilles are clean, and free of any potential obstructions.

 STORAGE

•  Your device should be stored in a room with a maximum  

ambient temperature of 25°C, free of any excessive humidity 

and not exposed to vibrations.

•  If the device sustains an impact, the integrity of the optical  

components should be checked. 

•  In case of any visible damage to the optical components: the  

filter

 (the flat component of red-coloured glass), the 

optical guide, the tube, etc., operation of the device should be 

discontinued immediately.

REMINDER:

Storage temperature : - 5°C to + 65°C.

Usage temperature : + 5°C to + 25°C.

To use and to store keeping a relative humidity under 93%.

IMPORTANT:

 Ensure that no liquid enters the ventilation 

grilles. 

Summary of Contents for E-Eye

Page 1: ...User Manual...

Page 2: ...nging and is a practical example of this fact Your patients can now enjoy the benefits of a new treatment for meibomian blepharitis dry eye syn drome using state of the art pulsed light technology wit...

Page 3: ...ETC The manufacturer s guarantee for parts and labour will only be valid if your device is returned in its complete original packaging All items of original packaging in which your was delivered shou...

Page 4: ......

Page 5: ...onal user of must ensure that only persons who fulfil the criteria for use described in the present manual will receive treatment using Before using your the following information should be read caref...

Page 6: ...lement for less than two months On an injured burned or infected skin On skin lesions of unusual appearance which will require investigation On high risk areas blemishes birthmarks warts unhealed woun...

Page 7: ...nection Activation card slot Applicator holding Ventilation grid Visor to protect touchscreen Mobile head Release clips for the mobile head Mobile head Applicator zone Applicator zone Air vents Trigge...

Page 8: ...use of the device 13 Pause icon for the flash treatment session pressing this icon will place in pause mode In this mode no flash can be emitted from the applicator To exit this mode press the same i...

Page 9: ......

Page 10: ...plicator photo 3 Push the extractor into the mobile head to its full length photo 4 Apply pressure simultaneously to the 2 retaining lugs of the mobile head and remove the mobile head photo 5 Remove t...

Page 11: ...nce entered these codes will not be requested a second time Connect using the mains lead The internal test procedure of will commence and will last for a few seconds Upon the completion of this phase...

Page 12: ...n a generous layer minimum 1cm thick on the cheekbone and the tempo ral areas making sure that the gel does not get under the eye mask Locate your mask goggles and put them on If there are other perso...

Page 13: ......

Page 14: ...tivation card and its optic cartridge must be replaced when the number of flashes reaches zero STAGE 2 COOLING OF OPTICAL PARTS During the procedure for the replacement of the optic cartridge before s...

Page 15: ...tridges are not symmetrical so they must be inserted in the right sense and certainly not in the other Check that the cartridge is correctly engaged PRECAUTIONS throughout the procedure for the replac...

Page 16: ...the old activation card and insert the new card supplied with the optic cartridge in the slot provided for this purpose photo I Each activation card carries the same serial number as the optic cartrid...

Page 17: ...on icon 7 The C key can be used to correct the figure in each box SELECT LANGUAGE screen L Click on the flag which corresponds to the required language The Language change confirmed message will be d...

Page 18: ......

Page 19: ...o danger or entail the risk of irreparable damage to your device Once o p t i c cartridge is removed it should be handled by the plastic parts only above all the electrodes the tube or the reflector s...

Page 20: ...sothiazolinone 0 05 0 15 Deionized water Q S 100 For external use only Not to be used on broken burned or infected skin Keep out of reach of children The tool extractor is used for the separation of t...

Page 21: ...of your device Never apply the clean spray directly to the internal components of the applicator APPLICATOR BODY All plastic components of the applicator must be cleaned using a clean cloth which has...

Page 22: ...ols of the optical parts of the applicator to end SECU 03 SECU 04 SECU 05 SECU 07 SECU 09 Your device is blocked Contact our technical department by filling out the contact form on www esw vision com...

Page 23: ...pheric pressure 70 106 kPa MARQUAGE Reference to the treatment of meibomian blepharitis dry eye syndrome using device Unique serial number of your E SWIN Rue des C tes d Orval ZA de la Pr v t 78550 Ho...

Page 24: ...considered If the measured field strength in the location in which the device is used exceed the applicable RF compliance level above the device should be observed to verify normal operation If abnor...

Page 25: ...or the applicator as you may risk exposure to high voltages Never use cartridges and acces sories other than those designated and sold by E Swin SAS for use with ENVIRONMENTAL PROTECTION You must abi...

Page 26: ...ns described in this manual will invalidate the guarantee The company E Swin SAS will not accept liability for any accident arising from failure to observe the instructions contained in this manual or...

Page 27: ...0197 ZA de la Pr v t Rue des C tes d Orval 78550 Houdan FRANCE 01 30 46 37 61 www esw vision com M029GB000F08A rev F 2021 06 11...

Reviews: