9
E-MORE 1M2S
Press the “S” key for 5 seconds to select between the different settings by using the UP or DOWN key. After you changed a
setting, you have to save the new setting by pressing the “S” key again.
S-1 Unit of measure
Press “S” and then select: 0 for cm, 1 for inches
S-2 Gyroscope sensor
Press “S” and then select: 0 = off, 1 = least sensitive to 8 = most sensitive
S-3 Anti-collision sensitivity moving up
Press “S” and then select: 0 = off (not recommended), 1 = least sensitive to 8
= most sensitive
S-4 Anti-collision sensitivity moving down
Press “S” and then select: 0 = off (not recommended), 1 = least sensitive to 8
= most sensitive
S-5 Display height
Press “S” and then using the up / down keys you can change the display
height if necessary
S-6 frame operating mode
Press “S” and then select: 0 = constant touch or 1 = one-touch
S-7 Duty cycle
To deactivate the overheating protection – please do not change!
S-8 frame tilt sensitivity
Press “S” and then select 0 = off, 1 = 0.5°, 2 = 1.0°, 3 = 1.5°, 4 = 2.0°, 5 = 2.5°, 6
= 3.0°, 7 = 3.5°, 8 = 4.0°
After adjusting all settings you have to press the “S” key again to return to the main menu.
Minimum /Maximum height
To select a minimum height do the following: Move the frame to the desired minimum height. Press the UP & Down key simul-
taneously for about 5 seconds. A beep indicates that the minimum height has been set. (IMPORTANT: You can only select a
minimum height that is below 96 cm)
To remove the minimum height please move the frame to the programmed minimum height, than press the Up & Down key
simultaneously until you hear a beep indicating that the minimum height was deleted.
To set/delete the maximum height please proceed the same way. The maximum height must be more than 97 cm.
HOW TO ADJUST SETTINGS BY USING THE HAND CONTROLSETS
TROUBLESHOOTING
Error Code
Possible Cause
How To Correct
E1, E6, E7
Power failure
Reconnect power - switch power source
E2
Lifting columns out of synch
Perform a reset as described under 1 .
E4
Handset fault
Unplug and plug in the cable of the handset
E5
Anti-collission warning
standard function, no corrective action required
E8
Desktop not level
Level the table
E11, E21
Motor fault
Check the motor wire connections
E12, E22
Control box failure
Control box needs to be replaced
E13
Connection problem
Check cables
E14 - E17 | E24 - E27
Motor failure
Motor / lifting column needs to be replaced
E18, E28
Overload protection
Reduce the weight
HOT
Excessive use
Do not use for 20 minutes. System will recover
automatically .