3
1. GENERAL
.............................................................................................................
4
1.1. Safety Instructions
..................................................................................................
4
1.1.1. Intended Use
...................................................................................................
4
1.1.2. Installation, start up and control
..................................................................................
5
1.2. Environmental aspects
..............................................................................................
5
2. PRODUCT DESCRIPTION
.......................................................................................
6
3. INSTALLATION
......................................................................................................
7
3.1. Mounting dimensions
...............................................................................................
7
3.1.1. Model Compact (EE771-A and EE771-B)
.........................................................................
7
3.1.2. Model remote sensing probe (EE771-C)
..........................................................................
7
3.2. Determining installation site
.........................................................................................
8
3.2.1. Process pressure
...............................................................................................
8
3.3. Installation position
..................................................................................................
9
3.4. Required length of straight pipe
.....................................................................................
10
3.5. Assembly of the measurement ball valve
...........................................................................
11
3.5.1. Assembly without flow meter, but with screw cap instead (blind cap)
................................................
11
3.5.2. Shut off the measurement ball valve
..............................................................................
11
3.6. Installation of the flow meter sensing probe
........................................................................
12
3.6.1. Flow direction
...................................................................................................
12
3.6.2. Installation of the sensing probe
..................................................................................
12
4. ELECTRICAL CONNECTIONS
.................................................................................
13
4.1. Connection diagram
.................................................................................................
13
4.1.1. Relay and pulse output, internal switching
........................................................................
13
4.1.2. Connection with optional plug for power supply and outputs (order code Q)
..........................................
13
4.2. Bus Output (optional)
...............................................................................................
14
4.2.1. M-Bus (Meter-Bus)
..............................................................................................
14
4.2.2. Modbus RTU
...................................................................................................
15
4.2.3. Data Transmission
..............................................................................................
15
4.2.4. Addressing
.....................................................................................................
15
5. CONTROL COMPONENTS
......................................................................................
16
5.1. Jumper J1 and J2
...................................................................................................
16
5.2. Digital interface USB ( for configuration)
............................................................................
16
5.3. Display / Indicator with keypad (optional)
...........................................................................
16
5.3.1. Indication of the analogue and pulse output
.......................................................................
17
5.3.2. Indication of the switch output
....................................................................................
17
5.3.3. Indication of the MIN / MAX values
...............................................................................
17
5.3.4. Reset of the consumption counter or the MIN / MAX value
.........................................................
18
5.3.5. Maximum consumption counter
..................................................................................
18
6. ERROR MESSAGES
..............................................................................................
18
7. MAINTENANCE
.....................................................................................................
19
7.1. Removal of the sensing probe of the flow meter
...................................................................
19
7.2. Cleaning of the sensor of the flow meter
...........................................................................
19
8. REPLACEMENT PARTS / ACCESSORIES
.................................................................
19
8.1. Order Code Replacement Sensor
..................................................................................
19
8.2. Order Code Miscellaneous
..........................................................................................
20
9. TECHNICAL DATA
.................................................................................................
20
9.1. Factory setting of outputs
...........................................................................................
21
Table of contents - HARDWARE
Table of contents - SOFTWARE
1. General
................................................................................................................
22
2. Installation
...........................................................................................................
23
2.1. Configuration of the USB Interface (VirtualCOM)
...................................................................
23
3. User Interface
.......................................................................................................
24
4. Menu toolbar
........................................................................................................
25
4.1. File
..................................................................................................................
25
4.2. Transmitter
..........................................................................................................
25
4.3. Extras
...............................................................................................................
25
5. Input Screen
.........................................................................................................
25
5.1. Output 1, Output 2
..................................................................................................
25
5.1.1. Output mode
...................................................................................................
25
5.1.2. Measurand
.....................................................................................................
25
5.1.3. Units
...........................................................................................................
25
5.1.4. Output mode – analogue
........................................................................................
26
5.1.5. Output mode – switch (relay)
....................................................................................
26
5.1.6. Output mode – pulse
............................................................................................
27
5.2. Minimum flow shutdown
............................................................................................
27
5.3. Display
..............................................................................................................
28
5.4. Adjustment
..........................................................................................................
28
5.4.1. 1-point adjustment
..............................................................................................
28
5.4.2. 2-point adjustment
..............................................................................................
29
5.4.3. Reset to factory settings
.........................................................................................
29
5.5. Measuring values overview
.........................................................................................
30
5.5.1. Reset of the MIN / MAX values
..................................................................................
30
5.5.2. Reset of the consumption counter (totalizer)
.......................................................................
30
5.6. Setting up Process Parameters
.....................................................................................
30
5.6.1. Change the Process Gas
........................................................................................
30
5.6.2. Changing the standard conditions
................................................................................
31
5.6.3. Pressure compensation
.........................................................................................
31
5.7. External pressure transmitter for pressure compensation
..........................................................
31
5.8. Bus configuration
....................................................................................................
31