A P P E N D I X C
EEC Finger Guards Installation
Above Ground Model 200iX/250iX Motorcycle Dynamometer Installation Guide
C-2
EEC FINGER GUARDS INSTALLATION
The EEC finger guards are secured to the drum module hood and provide extra
protection from the drum by regulating the distance between the drum and the
chassis. The placement of the finger guards can be manually adjusted.
R
EMOVING
THE
D
RUM
M
ODULE
H
OOD
Before installing the EEC finger guards, the dyno and iX drum module hoods must be
removed.
Never operate the dynamometer with the drum module hood removed.
CAUTION
Dynojet recommends using a T30 Torx driver (Snap-On PFTx30E) to
remove the 1/4-inch screws. For dynos with serial numbers lower than
2030152, Dynojet recommends using a hardened 5/32-inch hex driver
(such as Snap-On FA5E). A standard allen key may round off in the
shallow screw head.
1
Turn off the dyno and disconnect the power cord from its power source. Refer to
“Main Dyno Power” on page 3-2.
2
Remove the drum safety cover. This cover has two pins to keep it in place.
3
Remove the eight screws securing the dyno drum top cover and set aside. Remove
the dyno drum top cover and set aside.
4
Remove the eight screws securing the iX drum top cover and set aside. Remove
the iX drum top cover and set aside.
Figure C-1: Remove the Dyno and iX Drum Module Hoods
drum safety cover
dyno drum top cover
iX drum top cover