POWERCUBE User Manual
9
1. If the host is the latest B4850 battery with DIP switch:
(1) The communication cable that communicates with
the inverter should use the correct one.
(2) After the battery module parallel cable, cascading
cable and communication cable with GDW
、
Solis
、
LUX
、
Sofar
、
DEYE
、
VICTRON
、
IMEON
、
Infinisolar,Sungrow,SMA,RENAC,DELIOS
、
SAJ(CAN
Comm) inverters are connected, all B4850 batteries
should not be turned on first, be sure to put the host DIP
switch "# 3" to the "ON" position (to the top), then turn
on all the B4850 batteries.
(3) If the battery module is in communication with the
inverters of Growatt hybrid(CAN comm)
、
GMDE
、
Saj(485 comm)
、
Axpret-king turn the host DIP switch "#2" to "ON"
position.
(4) If the battery module is in communication with the
GROWATT-SPF(off-grid) inverter by 485 communication,
turn the host DIP switch "#2" and "#3" to "ON".
(5) The DIP switch of the slave does not need to be
changed.
(6) If the energy storage system has only one B4850, it is
the host itself, and still follow the above steps.
Note: For more information of matching inverter brands,
please subject to the latest document <The list of
compatibility between Dyness ESS and Inverters >.
2. If the host is a B4850 battery
module without the DIP switch:
(1) The communication cable that
communicates with the inverter
should use the correct one which
is supplied by DYNESS.
(2) After the battery module
parallel cable, cascade cable and
the inverter communication cable
are connected, turn on all B4850
batteries.
(3)Before connecting with
inverter,please ensure the no-dip
battery firmware vertion support
yours inverter.
Note: 1.After the whole system connection,set the master DIP mode according to the inverter
model firstly,then start the battery.
2.The BAT-INV comms cable is from inverter comm port to master CAN IN port,BAT-BAT
cable is from master CAN OUT to slave1 CAN IN,slave1 CAN OUT to slave2 CAN IN…