Diamond 10kW Manual
Dynatronix, Inc.
198-1603-03 Rev 01
Page 149 of 150
105
System
(0)
The FPGA code version does not
match on all inverters in the
system.
Manual Clear. This fault can be
cleared manually even if the
condition has not changed. This
fault is informational and does
not affect power supply
operation.
NO
YES
106
Output
Channel
(0 to n)
Reverse over current out of
tolerance fault. The average
current reading is greater than
the average current setting by
more than the specified tolerance
percent.
Tolerance faults can be
manually cleared at any time.
All tolerance faults are
automatically cleared at the start
of a cycle. If the fault condition
remains the fault is set again.
NO
YES
107
Output
Channel
(0 to n)
Reverse under current out of
tolerance fault. The average
current reading is less than the
average current setting by more
than the specified tolerance
percent.
Tolerance faults can be
manually cleared at any time.
All tolerance faults are
automatically cleared at the start
of a cycle. If the fault condition
remains the fault is set again.
NO
YES
108
Output
Channel
(0 to n)
Reverse over voltage out of
tolerance fault. The average
voltage reading is greater than the
average voltage setting by more
than the specified tolerance
percent.
Tolerance faults can be
manually cleared at any time.
All tolerance faults are
automatically cleared at the start
of a cycle. If the fault condition
remains the fault is set again.
NO
YES
109
Output
Channel
(0 to n)
Reverse under voltage out of
tolerance fault. The average
voltage reading is less than the
average votlage setting by more
than the specified tolerance
percent.
Tolerance faults can be
manually cleared at any time.
All tolerance faults are
automatically cleared at the start
of a cycle. If the fault condition
remains the fault is set again.
NO
YES
110
System
(0)
A new FPGA inverter
configuration was detected, it
does not match the previous
configuration. This can occur
when updating FPGA code in the
inverter or when swapping remote
controls or inverter controls.
Manual clear. Fault is
informational.
NO
YES
111
Inveter
Control
(0 to n)
Primary input voltage has
exceeded the DC bus voltage.
Output power is reduced until the
primary input voltage returns to
acceptable limits. Not applicable
for all models. Module A
Cleared when the primary input
voltage returns to acceptable
levels.
Outpu
power
reduced
YES
112
Inveter
Control
(0 to n)
Primary input voltage has
exceeded the DC bus voltage.
Output power is reduced until the
primary input voltage returns to
acceptable limits. Not applicable
for all models. Module B
Cleared when the primary input
voltage returns to acceptable
levels.
Outpu
power
reduced
YES
113
Inveter
Control
(0 to n)
Over temperature condition on the
reversing bridge.
Fault auto clears when the
temperature drops to a safe
level.
YES
YES
114
N/A
N/A
N/A
N/A
N/A