26
ILH800EN2
MAINTENANCE – EVERY 500 HOURS OF OPERATION
1. Replace fuel filter (See engine manual).
2. Change engine oil (See engine manual).
3. Replace oil filter (See engine manual).
4. Replace air cleaner element (See engine manual).
Hatz 1D90V
Save the oil and dispose of it in an approved
manner. Also dispose of used oil filters properly.
L000466A
Changing hydraulic fluid / filter
1. Remove the protecting cover.
2. Open hydraulic reservoir at filter and empty it by
using
a suitable pump. Collect the contents in a
receptacle.
3. Replace the hydraulic filter.
Save the oil and dispose of it in an approved
manner. Also dispose of used oil filters properly.
4. Fill with fresh hydraulic fluid up to the sight glass
level: 27,0 litre (7.1 gal)
5. Replace the filter and all covers.
2
1. Hydraulic filter
2. Sight glass
1
L000585A