3.
Loosen the fastening screws (1) and push the coupling down.
4.
Remove and replace the toothed belt (2).
5.
Mark the position of the exciter shafts (1) with a downward
arrow.
6.
Turn the left exciter shaft (2) by 180° and hold it in this posi-
tion.
7.
Install the new toothed belt (1).
8.
Use a suitable tool (e.g. spring balance) with a tensile force
of 90 – 120 N (66 – 89 lbs) to pull the coupling upwards until
the required compression measurement is reached.
ð
Compression measurement:
10 – 25 mm
(0.59 – 0.98 in).
9.
Tighten the fastening screws (1).
10.
Attach the cover.
Replacing the toothed belt
1
1
2
B-834-0275
Fig. 92
1
1
B-834-0276
Fig. 93
2
1
B-834-0277
Fig. 94
Tensioning the toothed belt
90 – 120 N
66 – 89 lbs
1
1
B-834-0273
Fig. 95
Maintenance – Annually
DTR75
96
Summary of Contents for DTR75
Page 2: ...2 ...
Page 6: ...10 Disposal 117 10 1 Final shut down of machine 118 Table of contents DTR75 6 ...
Page 7: ...1 Introduction Introduction DTR75 7 ...
Page 11: ...2 Technical data Technical data DTR75 11 ...
Page 15: ...3 Concerning your safety Concerning your safety DTR75 15 ...
Page 43: ...4 Indicators and control elements Indicators and control elements DTR75 43 ...
Page 48: ...Indicators and control elements Engine DTR75 48 ...
Page 49: ...5 Checks prior to start up Checks prior to start up DTR75 49 ...
Page 57: ...6 Operation Operation DTR75 57 ...
Page 69: ...7 Loading transporting the machine Loading transporting the machine DTR75 69 ...
Page 74: ...Loading transporting the machine After transport DTR75 74 ...
Page 75: ...8 Maintenance Maintenance DTR75 75 ...
Page 107: ...6 Check the oil levels 7 Clean the machine thoroughly Maintenance As required DTR75 107 ...
Page 108: ...Maintenance As required DTR75 108 ...
Page 109: ...9 Troubleshooting Troubleshooting DTR75 109 ...
Page 117: ...10 Disposal Disposal DTR75 117 ...
Page 119: ......
Page 120: ......