9.2 Malfunctions during operation
Fault
Possible cause
Remedy
The machines
vibrates forward
with a strongly
reduced speed
Air in the hydraulic system of the steering
rod
Release pressure from the steering rod
The oil level in the exciter shaft housing
is too low
Check the oil level in the exciter shaft
housing
Protective equipment:
n
Protective gloves
1.
Park the machine in secured condition
„Parking the machine in secured condition“ on page 57
.
2.
Press the travel lever forward against the end stop and hold it
in this position.
3.
Carefully loosen the adjustment screw (1).
ð
The air makes a slight hissing sound when escaping.
4.
Wait until all air has escaped and then tighten the adjustment
screw.
Release pressure from the steering
rod
Fig. 112
Troubleshooting – Malfunctions during operation
DRP20
101
Summary of Contents for DRP20
Page 2: ...2...
Page 6: ...Table of contents DRP20 6...
Page 7: ...1 Introduction Introduction DRP20 7...
Page 11: ...2 Technical data Technical data DRP20 11...
Page 15: ...3 Concerning your safety Concerning your safety DRP20 15...
Page 39: ...4 Indicators and control elements Indicators and control elements DRP20 39...
Page 42: ...Indicators and control elements Engine DRP20 42...
Page 43: ...5 Checks prior to start up Checks prior to start up DRP20 43...
Page 49: ...6 Operation Operation DRP20 49...
Page 59: ...7 Loading transporting the machine Loading transporting the machine DRP20 59...
Page 64: ...Loading transporting the machine Transport wheels DRP20 64...
Page 65: ...8 Maintenance Maintenance DRP20 65...
Page 99: ...9 Troubleshooting Troubleshooting DRP20 99...
Page 106: ...Troubleshooting What to do if the engine has flooded DRP20 106...
Page 107: ...10 Disposal Disposal DRP20 107...
Page 109: ...11 List of special tools List of special tools DRP20 109...
Page 111: ......
Page 112: ......