Maintenance - 50h
4812158801_E.pdf
2018-04-03
Battery cell
Fig. Electrolyte level in battery
1. Cell cap
2. Electrolyte level
3. Plate
10 mm
(0.4 in)
1
2
3
Take off the cell caps (1) and make sure that
electrolyte (2) is about 10 mm (0.4 in) above the plates
(3). Check the level of all cells. Top off with distilled
water to the right level if the level is low.
If the ambient temperature is below freezing, run the
engine for a while before topping off with distilled
water. Otherwise the electrolyte might freeze.
Make sure that ventilation holes in the cell cover are
not clogged, then put the cover back on.
The cable shoes should be clean and well tightened.
Clean corroded cable shoes and grease them with
acid-free Vaseline.
Always disconnect the negative cable first when
disconnecting the battery. When connecting the
battery, always connect the positive cable first.
Always disconnect the negative cable first when
disconnecting the battery. When connecting the
battery, always connect the positive cable first.
Discard used batteries wisely. Batteries contain
lead, which is harmful to the environment.
Discard used batteries wisely. Batteries contain
lead, which is harmful to the environment.
Before doing any electric welding on the machine,
disconnect the battery ground cable and then all
electrical connections to the alternator.
Before doing any electric welding on the machine,
disconnect the battery ground cable and then all
electrical connections to the alternator.
79
Summary of Contents for CC7200
Page 2: ......
Page 12: ...Introduction 4812158801_E pdf 2018 04 03 4...
Page 18: ...Safety Optional 4812158801_E pdf 2018 04 03 10...
Page 22: ...Special instructions 4812158801_E pdf 2018 04 03 14...
Page 66: ...Operating instructions Summary 4812158801_E pdf 2018 04 03 58...
Page 68: ...Preventive maintenance 4812158801_E pdf 2018 04 03 60...
Page 76: ...Maintenance Maintenance schedule 4812158801_E pdf 2018 04 03 68...
Page 88: ...Maintenance 50h 4812158801_E pdf 2018 04 03 80...
Page 101: ...Dynapac Compaction Equipment AB Box 504 SE 371 23 Karlskrona Sweden www dynapac com...