Maintenance - Lubricants and symbols
4812158801_E.pdf
2018-04-03
Maintenance - Lubricants and symbols
Always use high-quality lubricants and the
amounts recommended. Too much grease or
oil can cause overheating, resulting in rapid
wear.
Always use high-quality lubricants and the
amounts recommended. Too much grease or
oil can cause overheating, resulting in rapid
wear.
Fluid volumes
liters
gallon (U.S.)
Fluid volumes
liters
gallon (U.S.)
Hydraulic reservoir
120
31,7
Hydraulic reservoir
120
31,7
Hydraulic system
25
6,6
Hydraulic system
25
6,6
Pump gear
3,1
0,82
Pump gear
3,1
0,82
Drum
Drum
- Drum
53
14
- Drum
53
14
- Gear box
3
0,79
- Gear box
3
0,79
Diesel engine
Diesel engine
- Oil
15,7
4,1
- Oil
15,7
4,1
- Coolant
28
7,4
- Coolant
28
7,4
Other fuel and lubricants are required when
operating in areas with extremely high or
extremely low ambient temperatures. See the
‘Special instructions’ chapter, or consult
Dynapac.
Other fuel and lubricants are required when
operating in areas with extremely high or
extremely low ambient temperatures. See the
‘Special instructions’ chapter, or consult
Dynapac.
ENGINE OIL
Air temperature -15°C - +50°C
(5°F-122°F)
Dynapac engine oil 200
P/N 4812161855 (5 liters),
P/N 4812161856 (20 liters)
ENGINE OIL
Air temperature -15°C - +50°C
(5°F-122°F)
Dynapac engine oil 200
P/N 4812161855 (5 liters),
P/N 4812161856 (20 liters)
HYDRAULIC FLUID
Air temperature -15°C - +50°C
(5°F-122°F)
Dynapac hydraulic 300
P/N 4812161868 (20 liters),
P/N 4812161869 (209
liters)
HYDRAULIC FLUID
Air temperature -15°C - +50°C
(5°F-122°F)
Dynapac hydraulic 300
P/N 4812161868 (20 liters),
P/N 4812161869 (209
liters)
Air temperature over +40°C
(104°F)
Shell Tellus S2 V100
Air temperature over +40°C
(104°F)
Shell Tellus S2 V100
BIOLOGICAL
HYDRAULIC FLUID,
PANOLIN
Air temperature -10°C - +35°C
(14°F-95°F)
When it leaves the factory, the
machine may be filled with
biologically degradable fluid.
The same type of fluid must be
used when changing or topping
up.
PANOLIN HLP Synth 46
(www.panolin.com)
BIOLOGICAL
HYDRAULIC FLUID,
PANOLIN
Air temperature -10°C - +35°C
(14°F-95°F)
When it leaves the factory, the
machine may be filled with
biologically degradable fluid.
The same type of fluid must be
used when changing or topping
up.
PANOLIN HLP Synth 46
(www.panolin.com)
DRUM OIL
Air temperature -15°C - +40°C
(5°F-104°F)
Dynapac Gear oil 300
,
P/N 4812030756 (5 liters),
P/N 4812030117 (20 liters),
P/N 4812031574 (209
liters)
DRUM OIL
Air temperature -15°C - +40°C
(5°F-104°F)
Dynapac Gear oil 300
,
P/N 4812030756 (5 liters),
P/N 4812030117 (20 liters),
P/N 4812031574 (209
liters)
GREASE
Lubrication points in addition to
articulated joint
Dynapac Roller Grease
P/N 4812030096 (0.4kg)
GREASE
Lubrication points in addition to
articulated joint
Dynapac Roller Grease
P/N 4812030096 (0.4kg)
61
Summary of Contents for CC7200
Page 2: ......
Page 12: ...Introduction 4812158801_E pdf 2018 04 03 4...
Page 18: ...Safety Optional 4812158801_E pdf 2018 04 03 10...
Page 22: ...Special instructions 4812158801_E pdf 2018 04 03 14...
Page 66: ...Operating instructions Summary 4812158801_E pdf 2018 04 03 58...
Page 68: ...Preventive maintenance 4812158801_E pdf 2018 04 03 60...
Page 76: ...Maintenance Maintenance schedule 4812158801_E pdf 2018 04 03 68...
Page 88: ...Maintenance 50h 4812158801_E pdf 2018 04 03 80...
Page 101: ...Dynapac Compaction Equipment AB Box 504 SE 371 23 Karlskrona Sweden www dynapac com...