Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003
13
2.2.4 Power
connection
Make sure you are using the correct power source as the AC/DC adaptor. Inset the female end
of power adaptor’s cord into the power receptacle on the rear panel. Connect the power
adaptor to an appropriate power source.
2.2.5 Reset
Button
The reset button can be used only in one of two ways.
(1) Press the Reset Button for two second will cause system reboot.
(2) Pressing the Reset Button for eight seconds will cause the product loading the factory
default setting and losing all of yours configuration. When you want to change its
configuration but forget the user name or password, or if the product is having problems
connecting to the Internet and you want to configure it again clearing all configurations, press
the Reset Button for eight seconds with a paper clip or sharp pencil.
2.2.6
Protective Earth (Frame Ground) terminal
The marked lug or terminal should be connected to the building protective earth bus.
The function of protective earth does not serve the purpose of providing protection against
electrical shock, but instead enhances surge suppression on the DSL lines for installations
where suitable bonding facilities exist.
The connector type is M3 machine screw.