Dynamite Ultra AC/DC Charger/Cycler
www.DynamiteRC.com 13
li-ion/Poly Balance Charge
warning Message
WARN
Volt Select Err
1. Set Wrong Battery Voltage
Balancer
No Connect
2. Balance Leads not Connected
Unbalance Volt
Over 30mV
3. Shows that the unbalanced voltage is above
the 10mV limit at 30mV. The charge will
automatically switch to a 100mA charge rate
until the battery cell voltages are balanced to
less than 10mV. The charger will begin normal
charging after the cells are balanced.
Cell Number 1
Volt Over 4.26V
4. Battery voltage is over 4.26V per cell.
See previous step. The charger will drop to a
low current rate until the cells are balanced
within specifications.
li-ion/Poly Discharge Mode
Li-Poly Dischg
1.0A 12.0V(4S)
Message during li-ion/Poly Discharging
Li4S 0000:01 0001
DIS 1.00A 15.18V
See the status by turning the dial during
discharge.
Select Voltage
12.0V (4S)
1. Selected Discharge Voltage Cutoff
Discharge voltage is pre-set to 3.00V/cell and
the corresponding S count will be displayed
along side the voltage cutoff being selected.
Selecting the correct S count will automatically
set the appropriate voltage cutoff.
Input 13.01V
System Temp 36°C
2. DC Input Voltage/System Temperature