M
T
85
5.3.9
General User Options parameters
Parameter
Possible Values Default
Rev HHP Lite Std Adv
Chair Speed
0 – 10
10
C
Soft-Start Acceleration
No / Yes
No
A,C
-
Neutral Maximum
10 – 50 %
10 %
-,A,C
-
Disable OONAPU Faults
No / Yes
No
A,C
-
Speed Pot Scaler
20 – 100 %
100 %
-,A
-
Drive Delay After Power-up
0-10
0 s
C
-
Lock Enable
No / Yes
No
-,A,C
-
Sleep Mode Enable
No / Yes
No
-,A,C
-
Power-up Profile Number
1 - 7
7
C
-
Enable Joystick Wakeup
No / Yes
Yes
C
-
5.3.9.1
Chair Speed
Parameter
Possible Values Default
Rev HHP Lite Std Adv
Chair Speed
0 – 10
10
C
Chair Speed
is a digital Speed Pot parameter. Its value is sent as an input to the
global
Speed Pot
function (see section 5.3.1.2: Speed limiting options).
If
Chair Speed
is enabled with the
Chair Speed Enable
parameter (5.3.10.3), its value
can be easily edited with the HHP. Otherwise its value can only be set with the
Wizard.
5.3.9.2
Soft-Start Acceleration
Parameter
Possible Values Default
Rev HHP Lite Std Adv
Soft-Start Acceleration
No / Yes
No
A,C
-
Soft-Start Acceleration
temporary reduces the acceleration rate when the chair starts
driving from a standstill. This reduces the jerk when starting, particularly with high
acceleration rates or high load compensation settings.
Use the
Soft-Start Time
parameter to set the time during which Soft-Start Acceleration
is active (see 5.3.8.6).
5.3.9.3
Neutral Maximum
Parameter
Possible Values Default
Rev HHP Lite Std Adv
Neutral Maximum
10 – 50 %
10 %
-,A,C
-
Neutral Maximum
defines how far the joystick must be moved from the centre
position before the powerchair starts to move.
If this parameter is increased, the joystick must be deflected more to start driving.
This parameter affects all joysticks in the DX System.