4.5 Customizing the Program
Following examples show how to modify the parameters, save and compile the program before
making it ready to send to the logger.
Procedure to Modify the Program:
Open CR Basic Editor by clicking on CRBasic icon
.
Open the file Dynamet 5.CR1 in the editor.
Now identify the site-specific or timing loop variables at the top of the program as shown
in the previous above.
Modify values assigned to the constants as required.
Save the program under a different file name (Dynamet 5SiteA.cr1) so that the original
program is not modified. Save the program and compile.
Now the new program Dynamet 5SiteA.cr1 is ready to send to logger.
Example 1:
Dynamet 5 weather station is setup at a site that is only 50ft. above the sea level. The system is
installed on top of a tower whose height is 20m. Roughness parameter of the location of the
installation is found to be 0.001m and the specific air heat capacity is 1002.0 J/KgC. Modify the
program Dynamet 5.cr1 and send to logger so that the Dynamet 5 station can calculate ET
using the Lascano-VanBavel RCM algorithm.
From the program it is clear that the required station parameters are,
zom = 20 m
zot = 0.001 m
elf = 50 ft.
has = 1002.0 J/KgC
Open the program in Dynamet 5.CR1 in CRBasic. As shown below are the default parameters.
Summary of Contents for Dynamet 5
Page 1: ...DYNAMET 5 Weather Station User Manual v 1 1 ...
Page 3: ...Dynamax Inc 2 ...
Page 5: ...Dynamax Inc 4 ...
Page 18: ...Dynamet 5 17 ...
Page 19: ...Dynamax Inc 18 Dynamet 5 Logger Assembly wiring internal battery and solar charge regulator ...
Page 72: ...Dynamet 5 71 Logger 4 Logger 3 Logger 2 Logger 1 ...
Page 74: ...Dynamet 5 73 ...
Page 75: ...Dynamax Inc 74 ...
Page 79: ...Dynamax Inc 78 Appendix C SENSOR SPECIFICATIONS ...