background image

FOR UNITS USING THE CIRCUIT BOARD

DISCARD THE MOV AND THIS PAGE.

BLACK
WHITE
BLACK
WHITE

1
2
3
4

12 VOLT DC OPERATION

MOV

+

-

BLACK
WHITE
BLACK
WHITE

1
2
3
4

MOV

+

-

24 VOLT DC OPERATION

NOTE:  TO  PROTECT  OTHER  ELECTRONIC  DEVICES  IN  SYSTEM  CONNECT  THE  SUPPLIED  MOV  
ACROSS THE LEADS  AS  SHOWN  ABOVE.

NOTE:  TO  PROTECT  OTHER  ELECTRONIC  DEVICES  IN  SYSTEM  CONNECT  THE  SUPPLIED  MOV  
ACROSS THE LEADS  AS  SHOWN  ABOVE.

JUMPER

WIRING INSTRUCTIONS

Dyna

Lock

705 Emmett Street    Bristol, CT 06011-2728

 Phone:(860)582-4761   Fax:(860)585-0338

SERIES 2000/3000 x LCB

ELECTROMAGNETIC LOCK

Summary of Contents for 3000 Series

Page 1: ...Rating SPDT 0 5A DYNASTAT CONNECTOR TIME DELAY ADJ CW to increase Range 1 80 seconds see fig E 3000 2000 series mag lock accepts 12 24 VAC DC Circuit board shown fully loaded with every option ATS SWITCH LED 3 Pin Plug LOCK HOUSING Wht Wht 2 Pin Plug not polarized COIL CONNECTOR PLUG The Coil Connector is not polarized and may go on in either direction Blk Blk Wht Wht 4 Pin Plug COIL PLUG RECEPTAC...

Page 2: ...ICATORS NOT INCLUDED 12 24 VAC INPUT NORMALLY CLOSED STATION CONTROL S I E PUSHBUTTONS KEYSWITCHES ETC WIRE MULTIPLE CONTROLS IN SERIES AS SHOWN NORMALLY CLOSED STATION CONTROL S I E PUSHBUTTONS KEYSWITCHES ETC WIRE MULTIPLE CONTROLS IN SERIES AS SHOWN FIG D 3000 2000 DYNASTAT OPTION 3000 2000 DSM OPTION DOOR SECURE DOOR UNSECURE NOTES 1 DYNASTAT CONTACTS RATED 1A MAXIMUM 2 INDICATORS NOT INCLUDED...

Page 3: ... installation 2 For additional system wiring information refer to the installation documentation furnished with the external hardware and or peripheral devices I E power supply station controls keypad card readers etc supplied by DynaLock and or others 3000 2000 TD OPTION TIME DELAY 12 24 VAC VDC INPUT NORMALLY CLOSED STATION CONTROL S I E PUSHBUTTONS KEYSWITCHES ETC WIRE MULTIPLE CONTROLS IN SERI...

Page 4: ...L CONTACT BETWEEN THE MATING SURFACE OF THE LOCK AND ARMATURE MAGNET OVERHEATS LOCK SET FOR 12V WITH VERIFY THAT JUMPERS MATCH AND OR DRAWS EXCESS 24V APPLIED INPUT VOLTAGE SEE TOP OF PAGE 2 CURRENT POSSIBLE SHORTED COIL PERFORM THE COIL RESISTANCE CHECK REFER TO BOTTOM OF PAGE 3 DYNASTAT BOND SENSOR INSUFFICIENT SUPPLY VOLTAGE CHECK SUPPLY FOR PROPER INPUT NOT INDICATING DOOR VOLTAGE SHOULD BE WI...

Page 5: ...ngle models and 0 32 Amps for double models Damage may occur if input voltage exceeds 16V AC DC Do not attempt operation at higher voltages GENERAL INFORMATION BASIC INPUT POWER WIRING 3000 2000 x LP BASIC 12 VDC INPUT 12VDC INPUT FIG A NORMALLY CLOSED STATION CONTROL S I E PUSHBUTTONS KEYSWITCHS ETC WIRE MULTIPLE CONTROLS IN SERIES AS SHOWN 1 2 3 4 5 6 7 8 9 10 3000 2000 x LP BASIC 12 VAC INPUT 1...

Page 6: ...ION NOTE TO PROTECT OTHER ELECTRONIC DEVICES IN SYSTEM CONNECT THE SUPPLIED MOV ACROSS THE LEADS AS SHOWN ABOVE NOTE TO PROTECT OTHER ELECTRONIC DEVICES IN SYSTEM CONNECT THE SUPPLIED MOV ACROSS THE LEADS AS SHOWN ABOVE JUMPER WIRING INSTRUCTIONS DynaLock 705 Emmett Street Bristol CT 06011 2728 Phone 860 582 4761 Fax 860 585 0338 SERIES 2000 3000 x LCB ELECTROMAGNETIC LOCK ...