HOW TO SET VOLTAGE

Voltage is set by proper placement of the

 blue jumper caps on 4 exposed pins

Set for 12 Volts

2  jumpers

Removable Jumpers

Voltage Selection

Set for 24 Volts

1  jumper

FACTORY SET FOR 24 VOLTS

WIRING INSTRUCTIONS

3000/2000 

12/24 VDC INPUT

3000/2000 

12/24 VAC INPUT

(+)
    12 / 24 
    VDC
    INPUT
(-)

FIG. A

FIG. B

INPUT FROM
INDICATOR POWER  
SOURCE

DOOR CLOSED

DOOR OPEN

NOTES: 1. DSM CONTACTS RATED 
                   0.25A MAXIMUM
 

2. INDICATORS NOT INCLUDED

   12 / 24 
    VAC
    INPUT

NORMALLY CLOSED STATION 
CONTROL(S), I.E. PUSHBUTTONS, 
KEYSWITCHES, ETC.
WIRE MULTIPLE CONTROLS IN 
SERIES AS SHOWN.

NORMALLY CLOSED STATION 
CONTROL(S), I.E. PUSHBUTTONS, 
KEYSWITCHES, ETC.
WIRE MULTIPLE CONTROLS IN 
SERIES AS SHOWN.

FIG. D

3000/2000 DYNASTAT

OPTION

3000/2000 DSM 

OPTION

DOOR SECURE

DOOR UNSECURE

NOTES: 1.  DYNASTAT CONTACTS RATED  
 

     1A MAXIMUM

 

2.  INDICATORS NOT INCLUDED

INPUT FROM
INDICATOR POWER 
SOURCE

FIG. C

LOCK POWER INPUT

USE FIGURES 

OR 

B

}

}

LOCK POWER INPUT

USE FIGURES 

A

 OR 

B

2

C

NO

NC

NO

NC

C

1

     2       3      4     5     6      7     8      9     10

1

     2       3      4      5     6      7     8     9     10

1

     2       3      4     5     6      7     8     9     10

1

     2       3      4     5     6      7     8     9     10

Summary of Contents for 3000 Series

Page 1: ...Rating SPDT 0 5A DYNASTAT CONNECTOR TIME DELAY ADJ CW to increase Range 1 80 seconds see fig E 3000 2000 series mag lock accepts 12 24 VAC DC Circuit board shown fully loaded with every option ATS SWITCH LED 3 Pin Plug LOCK HOUSING Wht Wht 2 Pin Plug not polarized COIL CONNECTOR PLUG The Coil Connector is not polarized and may go on in either direction Blk Blk Wht Wht 4 Pin Plug COIL PLUG RECEPTAC...

Page 2: ...ICATORS NOT INCLUDED 12 24 VAC INPUT NORMALLY CLOSED STATION CONTROL S I E PUSHBUTTONS KEYSWITCHES ETC WIRE MULTIPLE CONTROLS IN SERIES AS SHOWN NORMALLY CLOSED STATION CONTROL S I E PUSHBUTTONS KEYSWITCHES ETC WIRE MULTIPLE CONTROLS IN SERIES AS SHOWN FIG D 3000 2000 DYNASTAT OPTION 3000 2000 DSM OPTION DOOR SECURE DOOR UNSECURE NOTES 1 DYNASTAT CONTACTS RATED 1A MAXIMUM 2 INDICATORS NOT INCLUDED...

Page 3: ... installation 2 For additional system wiring information refer to the installation documentation furnished with the external hardware and or peripheral devices I E power supply station controls keypad card readers etc supplied by DynaLock and or others 3000 2000 TD OPTION TIME DELAY 12 24 VAC VDC INPUT NORMALLY CLOSED STATION CONTROL S I E PUSHBUTTONS KEYSWITCHES ETC WIRE MULTIPLE CONTROLS IN SERI...

Page 4: ...L CONTACT BETWEEN THE MATING SURFACE OF THE LOCK AND ARMATURE MAGNET OVERHEATS LOCK SET FOR 12V WITH VERIFY THAT JUMPERS MATCH AND OR DRAWS EXCESS 24V APPLIED INPUT VOLTAGE SEE TOP OF PAGE 2 CURRENT POSSIBLE SHORTED COIL PERFORM THE COIL RESISTANCE CHECK REFER TO BOTTOM OF PAGE 3 DYNASTAT BOND SENSOR INSUFFICIENT SUPPLY VOLTAGE CHECK SUPPLY FOR PROPER INPUT NOT INDICATING DOOR VOLTAGE SHOULD BE WI...

Page 5: ...ngle models and 0 32 Amps for double models Damage may occur if input voltage exceeds 16V AC DC Do not attempt operation at higher voltages GENERAL INFORMATION BASIC INPUT POWER WIRING 3000 2000 x LP BASIC 12 VDC INPUT 12VDC INPUT FIG A NORMALLY CLOSED STATION CONTROL S I E PUSHBUTTONS KEYSWITCHS ETC WIRE MULTIPLE CONTROLS IN SERIES AS SHOWN 1 2 3 4 5 6 7 8 9 10 3000 2000 x LP BASIC 12 VAC INPUT 1...

Page 6: ...ION NOTE TO PROTECT OTHER ELECTRONIC DEVICES IN SYSTEM CONNECT THE SUPPLIED MOV ACROSS THE LEADS AS SHOWN ABOVE NOTE TO PROTECT OTHER ELECTRONIC DEVICES IN SYSTEM CONNECT THE SUPPLIED MOV ACROSS THE LEADS AS SHOWN ABOVE JUMPER WIRING INSTRUCTIONS DynaLock 705 Emmett Street Bristol CT 06011 2728 Phone 860 582 4761 Fax 860 585 0338 SERIES 2000 3000 x LCB ELECTROMAGNETIC LOCK ...