2. Keys
a
.
ON/OFF key
1
.
Pres
s “
ON/OFF”
Key 1 Second, the Dynamometer turn on.
2
.
In ON status
,
Press “
ON/OFF”
Key 1 Second
,
the Dynamometer turn off.
b. ZERO key
When Dynamometer switch on with no load, but there are small digits on the screen, press this
key to obtain the zero reading.
c. UNIT key
Press UNIT key, the unit on LCD will display circle as follows:
“kg”→ “lb” →“N” → “kN”→ “t”→
“kg” .
d. PEAK key
When load is changing, press this key will catch and display the maximum reading of the load.
Press this key again, reading will return to normal.
CHAPTER 3 WIRELESS INDICATOR OPERATION GUIDE
a
.
【
ON/OFF
】
1
.
Press “
ON/OFF”
Key 1 Second, the indicator turn on.
2
.
In ON status
,
Press “
ON/OFF”
Key 1 Second
,
the indicator turn off.
b
.
【
ZERO
】
1. In testing status ,there are small digits on screen, press this key to obtain the zero reading.
2.In Parameter Setting status
,
it used as scrolling up digit.
c
.
【
TARE
】
1. When there is tare weight such as container, after the reading stable, press this key, it will
display
“0”, and “
N
” indicator Flash.
2. Put the goods into container, the dynamometer will display goods net weight.
3. If move goods and container, the dynamometer will display minus value of tare weight.
4. In Parameter Setting status, it used as digits movement.