Press
【
ZERO
】
to choose
〖
Cd=12
〗
C: zero-tracking range, 0~5 total 6 options;
0=0d; 1=0.5d; 2=1d; 3=1.5d; 4=2d; 5=2.5d
d: display speed
,
0~2 total 3 options; 0=slow;
1=average; 2=fast; before calibration, set Cd=00 to
achieve high accuracy, after calibration, set Cd=11
again, generally choose Cd==12 when ex-stock..
Press
【
ENTER
】
to confirm
〖
LL=2
〗
New dynamometer, it display LL=2, if
dynamometer calibrated
,
it display calibrated
value.
Press
【
ZERO
】
to choose
〖
LL=1
〗
LL
:
filter parameter
,
0~5 total 6 options
,
from
smallest to biggest
,
before calibration, set
LL=0, after calibration, set LL=1 , generally
choose LL=1 when ex-stock..
Press
【
ENTER
】
to confirm
〖
Un=0
〗
New dynamometer, it display Un=0, if dyna-link
calibrated
,
the screen display calibrated unit.
Press
【
ZERO
】
to choose
〖
Un=0
〗
Choose unit
,
Un=0
:
kg, Un=1: lb, Un=2: N,Un=3: KN,
Un=4: ton, Generally, choose Un=0 when ex-stock.
Press
【
ENTER
】
to confirm
〖
OFF 1
〗
New dynamometer, it display OFF 1,if
dynamometer calibrated
,
it display calibrated value.
Press
【
ZERO
】
to choose
〖
OFF 2
〗
Choose turn off method, 0~2 total 3 options; 0: turn
off by hand; 1: if no operation, the screen
display ----- after 15minutes to save power; 2: if no
operation, the screen display ----- after
15minutes, and turn off automatically after
60minutes. Generally, choose OFF=2 when
ex-stock.
Press
【
ENTER
】
〖
SP1
〗
Set point 1
Press
【
ENTER
】
to confirm
〖
1 OFF
〗
New dynamometer, it display 1 OFF, if parameter
set, it display set value.
Press
【
ZERO
】
to choose
〖
1 HI
〗
or
〖
1 LO
〗
There are 3 choice,1 OFF means you don
’t set
point, 1 HI means the indicator will alarm when
load exceed the value you set, 1 LO means the
indicator will alarm when load smaller than the
value
Press
【
ENTER
】
to confirm
〖
02000
〗
New dynamometer it display 02000, if parameter
set, the screen display set value.
Press
【
ZERO
】
and
【
TARE
】
to
change value
〖
01000
〗
Set “1 HI” or “1 LO” Value. e.g. 1000kg
Press
【
ENTER
】
〖
SP2
〗
Set point 2
Press
【
ENTER
】
to confirm
〖
2 OFF
〗
New dynamometer, it display 2 OFF, if parameter
set, it display set value.
Press
【
ZERO
】
to
choose
〖
2 HI
〗
or
〖
2 LO
〗
There are 3 choice,2 OFF means you don
’t set
point, 2 HI means the indicator will alarm when
load exceed the value you set, 2 LO means the
indicator will alarm when load smaller than the
value
USER MANUAL 12