Standards
•
EN 50130-4
•
EN 50581
•
EN 55103-1/2
•
EN 61000-3-2/3
•
EN 61000-6-3
•
IEC 60065
•
EN 60945
Power consumption
230 V/50 Hz operation
I
supply
S
supply
P
supply
P
out
BTU/h
Standby
0.14 A
33.0 VA
1.9 W
0.0 W
6.5
Idle (no audio)
0.20 A
47.0 VA
19.5 W
0.0 W
66.5
Announcement (-10 dB)
0.88 A
202 VA
175 W
100 W
255.8
Alert (-3 dB)
3.35 A
772 VA
745 W
500 W
835.5
120 V/60 Hz operation
I
supply
S
supply
P
supply
P
out
BTU/h
Standby
0.09 A
9.0 VA
1.3 W
0.0 W
4.4
Idle (no audio)
0.27 A
29.0 VA
17.3 W
0.0 W
59.0
Announcement (-10 dB)
1.6 A
189 VA
175 W
100 W
255.8
Alert (-3 dB)
6.9 A
824 VA
800 W
500 W
1023
24 V DC operation
I
supply
S
supply
P
supply
P
out
BTU/h
Standby
0.06 A
-
1.4 W
0.0 W
4.8
Idle (no audio)
0.65 A
-
15.6 W
0.0 W
53
Announcement (-10 dB)
7.0 A
-
168 W
100 W
232
Alert (-3 dB)
32.5 A
-
780 W
500 W
938
Description of table columns:
•
I
supply
= RMS current drawn from mains (or DC supply)
•
S
supply
= apparent power drawn from the mains line
•
P
supply
= reactive power drawn from mains (or DC supply)
•
P
out
= NF output power provided to the speaker lines
•
P
loss
or BTU/h = thermal loss
10.1
10.2
30
en | Technical data
Promatrix 6000 Amplifier
18-Jun-2015 | 04 | F01U306848
Operation manual