Technical data
Specification
Rated load impedance (output power)
•
100 V
20 Ω (500 W)
•
70 V
10 Ω (500 W)
Rated output power, 1 kHz, THD ≤ 1%
2
✕
500 W
1
Rated input voltage
+6 dBu
Max. RMS voltage swing, 1 kHz, THD ≤ 1%, without load
•
100 V
110 V
•
70 V
78 V
Voltage gain, ref. 1 kHz, fixed
•
70 V
33.2 dB
•
100 V
36.2 dB
Maximum load capacitance
2 µF
Input level, max.
+18 dBu (9.75 V
rms
)
Frequency response, ref. 1 kHz, rated load,
-3 dB
50 Hz to 25 kHz
Input impedance, active balanced
20 kΩ
Signal-to-noise ratio (A-weighted)
> 104 dB
Output noise (A-weighted)
< -62 dBu
Crosstalk , ref. 1 kHz
< -85 dB
Output stage topology
Class-D, transformer, floating
Power requirements
•
AC
115–240 V (-10/+10%)
2
•
DC
21‑32 V
Power consumption, AC and DC
See section “Power consumption” in
operation manual
Inrush current
2 A
Inrush current, after five-second power cycle
1.3 A
Mains fuse
T6.3A (internally)
DC fuse
30A (internally)
Ground fault
R < 50 kΩ
CAN BUS port
2
✕
RJ-45, 10 to 500 kbit/s
10
28
en | Technical data
Promatrix 6000 Amplifier
18-Jun-2015 | 04 | F01U306848