background image

IPX Series DSP Multichannel
Networking Power Amplifier

IPX5:4 | IPX10:4 | IPX10:8 | IPX20:4

en

Installation manual

Summary of Contents for IPX10:4

Page 1: ...IPX Series DSP Multichannel Networking Power Amplifier IPX5 4 IPX10 4 IPX10 8 IPX20 4 en Installation manual ...

Page 2: ......

Page 3: ...acking and inspection 9 3 4 Scope of delivery 10 4 Planning information 11 5 Installation 12 5 1 Mounting 12 5 2 Mains power connection 12 5 3 Power 12 5 4 Ventilation 12 6 Controls indicators and connections 14 6 1 Front panel 14 6 2 Rear panel 14 6 3 Control port 14 6 4 Power outputs 15 6 5 Audio inputs 16 6 6 Fan cooling 16 7 Power amplifier menu navigation 17 7 1 Display and control menu 17 7 ...

Page 4: ...e lightly injured if the alert is not observed Warning The equipment or the property can be seriously damaged or persons can be severely injured if the alert is not observed Danger Not observing the alert can lead to severe injuries or death 1 2 Important safety instructions Danger The lightning symbol inside a triangle notifies the user of high voltage uninsulated lines and contacts inside the de...

Page 5: ...r any object enters the device if the device has been used in rain or become wet or if the device has been dropped or no longer works correctly 14 Please ensure that no dripping water or spray can penetrate the inside of the device Do not place any objects filled with fluids such as vases or drinking vessels on top of the device 15 To ensure the device is completely free of voltage unplug the devi...

Page 6: ...y the connected speaker systems especially when the amplifier is operated in bridge mode Prior to connecting any loudspeakers make sure to check the speaker system s specifications for continuous and peak power handling capacities Even if amplification has been reduced through lowering the input level controls on the amplifier s front panel it is still possible to achieve full power output with a ...

Page 7: ...nical photocopying recording or otherwise without the prior written permission of the publisher For information on getting permission for reprints and excerpts contact Dynacord All content including specifications data and illustrations in this manual are subject to change without prior notice NEUTRIK speakON powerCON and etherCON are registered trademarks of Neutrik AG IT security disclaimer In o...

Page 8: ...perating and maintaining the IPX multi channel amplifier This manual is intended for installers operators and users of IPX series powered amplifier systems Read through this manual to familiarize yourself with the safety information features and applications before you use these products 2 2 Digital document This manual is available as a digital document in the Adobe Portable Document Format PDF Y...

Page 9: ...e operation High efficiency Eco Rail technology for lower operating costs IPX10 8 features 8 x 1250 W multichannel installation DSP amplifier with digitally controlled PFC supply Fully integrated DSP with native 96 kHz and FIR Drive technology Dante and OCA integration via OMNEO with fallback options Parallel Bridge and Parallel bridge modes with 70 100 140 200 V and low impedance operation High e...

Page 10: ...very IPX5 4 IPX10 4 and IPX20 4 components Quantity Component 1 IPX series DSP power amplifier 1 8 pin Euroblock type connector Output 6 mm 2 6 pin Euroblock type connector Input 1 8 pin Euroblock type connector GPIO 4 M6x20 screw for rack mounting 1 Installation manual 1 Mains power connector 32 A with safety assembly instruction 1 Safety instruction booklet IPX10 8 components Quantity Component ...

Page 11: ...als No liquids can spill into or on the products Installation is in a clean environment free of dust The ventilation airflow of the 19 units is not obstructed There is a mains power outlet of sufficient rating close to the intended location of the products Sufficient free space and access at the rear of the 19 units for connectors and wiring To find current user documentation firmware or software ...

Page 12: ...g installation always separate the power amplifier from the mains Connect the power amplifier only to a mains network which corresponds to the requirements indicated on the type plate See also Accessories page 31 5 3 Power The IPX power switch is located on the rear panel of the power amplifier Press the switch towards the label ON powers on the amplifier Press the switch to the other side powers ...

Page 13: ...entilation louvers free from dust to ensure unhindered airflow Notice Do not use the power amplifier in direct sunlight or near heat sources like heater blowers stoves or any other heat radiating devices Notice Do not use the power amplifiers in an environment where temperatures are below 5 C 41 F or exceed 40 C 104 F For fixed amplifier installations in a device control room that incorporate a ce...

Page 14: ...r vent for amplifier cooling Do not obstruct 4 Audio inputs channels 1 2 3 4 5 Status LED indicating faults 6 MAINS IN AC mains input socket 7 Exhaust air vent for PSU Do not obstruct 8 Power amp outputs Euroblock channels 1 2 3 4 Class 3 wiring 9 Power amp outputs Euroblock channels 5 6 7 8 Class 3 wiring IPX10 8 only 10 Audio inputs channels 5 6 7 8 IPX10 8 only 11 Control port GPIO connector 12...

Page 15: ...ar panel Normal mode Figure 6 4 Normal mode Bridge mode cabling In Bridge mode both amp channels work in push pull operation to provide doubled output voltage In bridge mode operation speaker connection has to be established using pins 1 and 2 resp 3 and 4 5 and 6 7 and 8 on IPX10 8 see illustration Caution In Bridge mode operation it is not allowable for the load connected to all below a value of...

Page 16: ...easy pre wiring of the cables outside the rack and a fast single connector for connecting multiple channels at once without the danger of wiring errors HOT COLD JUMPER FROM COLD TO SHIELD SHIELD SHIELD HOT Figure 6 6 Input connectors wiring for balanced operation wiring for unbalanced operation The pin out is labeled on the rear of the amplifier It is highly recommended to use a balanced input cab...

Page 17: ... Eco Rail mode when no or small audio signal e g pilot tones or background music which results in a significantly reduced power consumption compared to other amplifiers see specifications for power consumption The amplifier is ready for operation when the Power ON switch on the rear panel is in position ON and the green POWER LED on the front panel is steady Turning on Standby mode If no audio sig...

Page 18: ... F 01U 330 705 Installation manual Bosch Security Systems Inc 7 3 Remote control via software IPX amplifiers can be completely remote controlled and supervised via the IRIS Net software For further instructions refer to the IRIS Net manual available in the download section of our website www dynacord com ...

Page 19: ...0 W 2500 W Number of Amplifier Channels 4 Maximum Output Voltage Normal mode per channel 150 Vpeak Maximum Output Current Normal mode per channel 41 Apeak AMPLIFIER Voltage Gain Low Z mode ref 1 kHz 32 0 dB adjustable 20 0 44 0 dB Direct Drive mode 33 2 36 2 39 2 42 2 dB for 70 100 140 200 V Input Sensitivity Low Z mode Max Output Voltage 10 7 dBu 2 66 V adjustable 1 3 22 7 dBu Direct Drive mode 6...

Page 20: ...vel equal to digital input 21 dBu for 0 dBFS Speaker Output 1 x 8 pin Euroblock 6mm female GENERAL Power Consumption Rated power consumption see BTU table 700 W 1 8 Maximum Output Power at 4 Ω 900 W Idle Mode no input signal 75 W Standby Mode 15 W Dimensions W x H x D mm 483 x 88 1 x 514 2 Weight 14 3 kg 31 5 lb Shipping Weight 16 5 kg 36 4 lb Amplifier at rated conditions Low Z Normal operation m...

Page 21: ...plifier Channels 4 Maximum Output Voltage Normal mode per channel 150 Vpeak Maximum Output Current Normal mode per channel 53 Apeak AMPLIFIER Voltage Gain Low Z mode ref 1 kHz 32 0 dB adjustable 20 0 44 0 dB Direct Drive mode 33 2 36 2 39 2 42 2 dB for 70 100 140 200 V Input Sensitivity Low Z mode Max Output Voltage 10 7 dBu 2 66 V adjustable 1 3 22 7 dBu Direct Drive mode 6 dBu 1 55 V fixed THD 3...

Page 22: ...al input 21 dBu for 0 dBFS Speaker Output 1 x 8 pin Euroblock 6 mm female GENERAL Power Consumption Rated power consumption see BTU table 1200 W 1 8 Maximum Output Power at 4 Ω 1765 W Idle Mode no input signal 80 W Standby Mode 16 W Dimensions W x H x D mm 483 x 88 1 x 514 2 Weight 15 0 kg 33 0 lb Shipping Weight 17 2 kg 37 8 lb Amplifier at rated conditions Low Z Normal operation mode all channel...

Page 23: ...lifier Channels 8 Maximum Output Voltage Normal mode per channel 150 Vpeak Maximum Output Current Normal mode per channel 41 Apeak AMPLIFIER Voltage Gain Low Z mode ref 1 kHz 32 0 dB adjustable 20 0 44 0 dB Direct Drive mode 33 2 36 2 39 2 42 2 dB for 70 100 140 200 V Input Sensitivity Low Z mode Max Output Voltage 10 7 dBu 2 66 V adjustable 1 3 22 7 dBu Direct Drive mode 6 dBu 1 55 V fixed THD 3 ...

Page 24: ...al input 21 dBu for 0 dBFS Speaker Output 2 x 8 pin Euroblock 6 mm female GENERAL Power Consumption Rated power consumption see BTU table 1300 W 1 8 Maximum Output Power at 4 Ω 1780 W Idle Mode no input signal 105 W Standby Mode 18 W Dimensions W x H x D mm 483 x 88 1 x 514 2 Weight 16 8 kg 37 1 lb Shipping Weight 19 1 kg 42 1 lb Amplifier at rated conditions Low Z Normal operation mode all channe...

Page 25: ...um Output Voltage Normal mode per channel 210 Vpeak Maximum Output Current Normal mode per channel 84 Apeak AMPLIFIER Voltage Gain Low Z mode ref 1 kHz 32 0 dB adjustable 20 0 44 0 dB Direct Drive mode 33 2 36 2 39 2 dB for 70 100 140 V Input Sensitivity Low Z mode Max Output Voltage 13 7 dBu 3 73 V adjustable 1 7 25 7 dBu Direct Drive mode 6 dBu 1 55 V fixed THD 3 dB below max AES17 1 kHz 0 05 DI...

Page 26: ... level equal to digital input 21 dBu for 0 dBFS Speaker Output 1 x 8 pin Euroblock 6 mm female GENERAL Power Consumption Rated power consumption see BTU table 2250 W 1 8 Maximum Output Power at 4 Ω 2850 W Idle Mode no input signal 110 W Standby Mode 19 W Dimensions W x H x D mm 483 x 88 1 x 514 2 Weight 18 3 kg 40 3 lb Shipping Weight 20 5 kg 45 1 lb Amplifier at rated conditions Low Z Normal oper...

Page 27: ...ectable as PEQ Lo Shelv Hi Shelv Hi Pass Lo Pass and All Pass Speaker X Over Hi Pass and Lo Pass per channel 6 12 18 24 30 36 42 48 dB Bessel Butterworth 12 24 48 dB Linkwitz Riley Alignment Delay 0 to 20 ms per channel Speaker FIR Up to 1025 taps Linear Phase Filter Linear Phase Brickwall X Over Speaker Limiters Peak Anticipation Limiter and RMS TEMP Limiter per channel Other Functions Source Sel...

Page 28: ...ating elements Mains Switch Power Requirements 100 V to 240 V 50 Hz to 60 Hz AC Power Supply Topology Switching Mode Power Supply with digital controlled Power Factor Correction Protections Audio Limiters High Temperature DC HF Short Circuit Back EMF Peak Current Limiters Inrush Current Limiters Turn on Delay Mains Circuit Breaker Protection Mains Over Under voltage Protection Cooling Front to rea...

Page 29: ...t Filter Pilot Detect Filter Pilot Detect Filter Pilot Detect Filter OMNEO OCA Network Interface DANTE Source Fail Detection Output Pilot Supervision Load Supervision see below optional Link SPEAKER PROCESSING SPEAKER PROCESSING SPEAKER PROCESSING op onal Link optional Link ADC Pilot Detect Filter ADC Pilot Detect Filter see below SPEAKER PROCESSING DELAY 0 to 2000 ms 686 mtr 2252 ft LEVEL MUTE DE...

Page 30: ...30 en Technical data IPX Series DSP Multichannel Networking Power Amplifier 2018 04 01 F 01U 330 705 Installation manual Bosch Security Systems Inc 8 8 Dimensions Figure 8 2 Dimensions IPX ...

Page 31: ...owing accessories are available for the IPX amplifiers CTN Description PD32 EU Power distro 3x32A 230V CEE 32A PD30 US Power distro 3x30A 208V NEMA L21 30 PCO32A30 US Power cord powerCon32 NEMA L6 30 PCO32A16 EU Power cord powerCon32 CEE7 7 PCO32A16 UK Power cord powerCon32 BS1363 PCO32A10 AU Power cord powerCon32 AU3 pin10A RMK 15 Rear rack mount kit for amplifiers ...

Page 32: ...Bosch Security Systems Inc 130 Perinton Parkway Fairport NY 14450 USA www dynacord com Bosch Security Systems Inc 2018 ...

Reviews: