14
en | Controls, indicators, and connections
IPX Series DSP Multichannel Networking Power
Amplifier
2018.04 | 01 | F.01U.330.705
Installation manual
Bosch Security Systems, Inc.
6
Controls, indicators, and connections
6.1
Front panel
1
2
3
Figure
6.1: IPX front panel
1.
OLED display for amplifier status and level information.
2.
Menu navigation buttons, up, down, and enter for display changes and editing.
3.
Amplifier status indications:
POWER LED indicates power on status.
STANDBY LED indicates standby status.
FAULT detect LED indicates a fault message.
OMNEO present LED indicates OMNEO network is present.
6.2
Rear panel
6
10
11
12
4
5
9
8
3
2
1
7
Figure
6.2: IPX rear panel
1.
Power ON switch.
2.
Ground contact.
3.
FAN - Exhaust air vent for amplifier cooling. Do not obstruct!
4.
Audio inputs channels 1, 2, 3, 4.
5.
Status LED, indicating faults.
6.
MAINS IN - AC mains input socket.
7.
Exhaust air vent for PSU. Do not obstruct!
8.
Power amp outputs Euroblock channels 1, 2, 3, 4 - Class 3 wiring.
9.
Power amp outputs Euroblock channels 5, 6, 7, 8 - Class 3 wiring (IPX10:8 only).
10. Audio inputs channels 5, 6, 7, 8 (IPX10:8 only).
11. Control port (GPIO) connector.
12. PRIMARY and SECONDARY OMNEO/Dante network connector (EtherCON/RJ45).
6.3
Control port
The control port features three GPIOs (general purpose in & outputs) and a ready and fault
contact. It is equipped with an 8-pin Euroblock type connector. Three GPIOs can be defined
by the user to change parameters of the amplifier or get parameter indication to external
devices. They are configurable for analog in, digital in or digital out. The other two ports are
potential free relay toggle contacts for READY or FAULT indication.
Summary of Contents for IPX10:4