49
Question:
How do I replace a 4-tone gong signal by a 3-tone gong? In accordance to the factory presets, the trigger is
connected to the control input B3 and it should stay that way.
Solution:
Performing the following changes is only possible for user 3!
The sequence S 25 which initiates the 4-tone gong signal G 20 is being started using the input B3. The
selected 4-tone gong signal G 20 has to be changed to the 3-tone gong signal G21 by altering line 9 of
sequence S 25 (see also on page 39). After selecting an unused user program memory number (e. g. S 05),
the displayed question ”store?” has to be answered with ”yes” to store the new settings. Select the trigger B3
in the ”trigger” menu and change the start sequence from S 25 to S 05. Using the soft key ”set” activates the
new trigger setting.
Question:
I would like to use the startlstop function of the factory presets S 28, S 30 for playback and remote recording
of the message M 02 (see also on page 36, 4014 1). My installation should include the inputs B3 and B4
instead of the inputs C3 and C4 reserved in the preset. The indication lamps are not needed which makes
retrofitting the port C not necessary.
Solution:
Performing the following changes is only possible for user 3!
For when the indication signals are not needed, the steps of the sequences S 28 (play message M 02) and S
30 (record M 02) stay unaltered. Only the button C4’s stop operation is altered into B4 in the sequence S 30.
The new setting is re-stored under S 30. The trigger B3 is selected in the ”trigger” menu and the start
sequence is changed from S 25 into S 28. Confirming the soft key ”set” activates this new setting (play M 02).
Now, you have to select the trigger B4 and change the start sequence S 26 into S 30. Afterwards confirm your
settings (record M 02) using the soft key ”set”.