3 Tests and Diagnostics
dynaEdge DE200 Series Maintenance Manual (960-947) [CONFIDENTIAL]
3-3
3.2 How to execute the test program
To start the test program for the maintenance, follow these steps below:
Step 1: Connect a USB Type-C adapter, a display, a keyboard (with function keys), a mouse
(and a USB hub, if needed), a AC adapter and a power cord to the computer.
Step 2: Turn on the computer while pressing
F2
of the keyboard to display the BIOS setup
program.
If Windows starts, shut down the computer while pressing
Shift
. Then repeat Step 2.
Step 3: Set [Security] menu – [Secure Boot] to [Disabled].
Step 4: Select [Exit] menu – [Save Changes and Power Off] to turn off the power.
Step 5: Insert the USB memory which includes the test program into the USB connector.
Step 6: Turn on the computer while pressing
F12
of the keyboard.
Step 7: Chose USB Memory on the selection screen, and press
Enter
of the keyboard.
(example screen)
Step 8: Then this program executes the followings automatically.
Procedure 1: Check of hardware information
The program checks and displays the hardware information such as HDD and
SSD of the computer.
When a system board is exchanged and DMI information has not been written
in, the DMI information can be registered with this program.
Refer to 3.3 Entry of the DMI information for details.
Summary of Contents for dynaEdge DE200 Series
Page 11: ...Chapter 1 Hardware Overview ...
Page 12: ...1 Hardware Overview 1 ii CONFIDENTIAL dynaEdge DE200 Series Maintenance Manual 960 947 ...
Page 31: ...Chapter 2 Troubleshooting Procedures ...
Page 83: ...Chapter 3 Tests and Diagnostics ...
Page 84: ...3 Tests and Diagnostics 3 ii CONFIDENTIAL dynaEdge DE200 Series Maintenance Manual 960 947 3 ...
Page 127: ...Chapter 4 Replacement Procedures ...
Page 128: ...4 Replacement Procedures 4 ii CONFIDENTIAL dynaEdge DE200 Series Maintenance Manual 960 947 ...
Page 132: ...4 Replacement Procedures 4 vi CONFIDENTIAL dynaEdge DE200 Series Maintenance Manual 960 947 ...
Page 201: ... CONFIDENTIAL Appendices ...
Page 202: ...Appendices App ii CONFIDENTIAL dynaEdge DE200 Series Maintenance Manual 960 947 ...
Page 204: ...Appendices App iv CONFIDENTIAL dynaEdge DE200 Series Maintenance Manual 960 947 ...