2 Troubleshooting Procedures
dynaEdge DE200 Series Maintenance Manual (960-947) [CONFIDENTIAL]
2-13
Check 1 Convert the flashing pattern of the DC IN/Battery indicator into the hexadecimal
error code and compare it to the tables below to clarify the cause of error.
Table 2-3
Error code
Error name
Error code
Conditions
Support
AC adapter 0 [A] correction
value error
10h
Error detection &
400 mA current default value
Not
support
AC adapter DC supply current
over rating
11h
AC adapter connection &
AC adapter current value >
DC-In normal current upper limit value
Not
support
AC adapter DC supply current
no load over
12h
AC adapter all power off &
Charge stop &
AC adapter current > 0.5A
Not
support
AC adapter over rating
13h
AC adapter voltage >
DC-In normal current upper limit value
Support
DC adapter over rating
14h
Dock AC adapter voltage >
DC-In normal voltage upper limit
Not
support
Output error at power start of
E system power supply
20h
During power on sequence,
Waiting for PCNFEV signal assertion
1s timeout occurred
Support
Steady-state output error at
power on of E system power
supply
21h
At power on steady time,
PCNFEV signal deassertion
Support
Steady-state output error at
power off of E system power
supply (No output)
22h
Power off steady state &
When the PCNFEV signal is
deasserted with the EVON signal
asserted
Support
Steady-state output error at
power off of E system power
supply (With output)
23h
Power off steady state &
When the PCNFEV signal is asserted
with the EVON signal deasserted
Support
Output error at startup of
system B power supply
30h
1s timeout occurs while waiting for
PCNFBV signal assertion during power
on sequence
Support
B system power supply ON
steady output error
31h
PCNFBV signal deassertion at power
on steady state
Support
B system power supply OFF
steady output error (No
output)
32h
Power off steady state &
PCNFBV signal deasserted when
BVON signal is asserted
Support
B system power supply OFF
steady output error (With
output)
33h
Power off steady state &
PCNFBV signal asserted when BVON
signal is deasserted
Support
Output error at P system and
CPU system power supply
startup
40h
1s timeout waiting for PPVOK
(PCNFPV) signal assertion occurred
during power on sequence
Support
P system and the CPU
system power supply On the
steady-state output error
41h
At power on steady time,
PPVOK (PCNFPV) signal deassertion
Support
P system and the CPU
system power supply Off the
steady-state output error
(With output)
43h
At power off steady time,
PPVOK (PCNFPV) signal assertion
Support
Summary of Contents for dynaEdge DE200 Series
Page 11: ...Chapter 1 Hardware Overview ...
Page 12: ...1 Hardware Overview 1 ii CONFIDENTIAL dynaEdge DE200 Series Maintenance Manual 960 947 ...
Page 31: ...Chapter 2 Troubleshooting Procedures ...
Page 83: ...Chapter 3 Tests and Diagnostics ...
Page 84: ...3 Tests and Diagnostics 3 ii CONFIDENTIAL dynaEdge DE200 Series Maintenance Manual 960 947 3 ...
Page 127: ...Chapter 4 Replacement Procedures ...
Page 128: ...4 Replacement Procedures 4 ii CONFIDENTIAL dynaEdge DE200 Series Maintenance Manual 960 947 ...
Page 132: ...4 Replacement Procedures 4 vi CONFIDENTIAL dynaEdge DE200 Series Maintenance Manual 960 947 ...
Page 201: ... CONFIDENTIAL Appendices ...
Page 202: ...Appendices App ii CONFIDENTIAL dynaEdge DE200 Series Maintenance Manual 960 947 ...
Page 204: ...Appendices App iv CONFIDENTIAL dynaEdge DE200 Series Maintenance Manual 960 947 ...