BlueWave® QX4® User Guide
23
Inputs
SIGNAL NAME/
DESCRIPTION
ASSERTED
DEASSERTED
0V
24V
PLC SENSE
The unit enters PLC mode.
The front panel will display
the PLC screen. The front
panel will be locked. All PLC
inputs will be monitored. All
PLC Outputs will be active.
The unit enters normal mode.
The front panel will be
unlocked. All PLC Inputs will
be ignored. All PLC Outputs
will be inactive.
INTERLOCK
Front panel displays lock
screen. Front panel will be
locked. All wands will be
shut off. All wants will be
disabled.
All LED heads will function
normally.
EXPOSURE 1->4
(Timed Mode)
LED head
“n” will start its
program. LED head
“n”
must complete its program
before another assertion
will be recognized.
LED head
“n” ready for next
assertion
EXPOSURE 1->4
(Manual Mode)
LED head
“n” will turn on
.
LED head
“n” will turn off
.
EXPOSURE ALL
All LED heads currently not
running a program will start
their program.
Ready for next assertion.
RESERVED
Not used at this time
GND
User signal ground
PROGRAM 1 -> 3
Select current program (Table 1)