BlueWave® MX-275 Emitter User Guide
11
Mounting/Connection
The
BlueWave
MX-275 emitter has two sets of M3 x 0.5 mm holes that
align with Dymax mounting stands and holders. Refer to Figure 2 for
mounting hole locations.
Figure 2. Dimensions - BlueWave® MX-275 Emitter
When connecting the emitter to an MX-series controller, ensure proper
strain relief to prevent pinching or kinking of the interconnect cable.
The cooling air intake on top of the unit must be free flowing. Do not
cover.
The exhausting air vents located on the side of the emitter must be given
at least 1 mm of clear space from obstructions for safe use.
When used in array format 1 mm of clear space between units must be
maintained and outermost units must have 20 mm to obstructions for
safe use.