28
USE R GUI DE
|
BL UE WAVE
®
A X -5 5 0
To run a curing cycle in PLC mode:
1.
Assert the PLC ENABLE input (connect the input to COM), PLC screen should appear.
2.
Set the intensity level source by toggling the LED INTENSITY INT/EXT line. INTERNAL mode uses the value set in the
controller. EXTERNAL source requires a voltage input based on a 1 volt DC = 10% power up to 10 volts DC for 100%.
3.
Assert both MASTER INTERLOCK and LED INHIBIT (connected both to COM), then assert the LED ON/OFF line, the
system starts the irradiation, irradiation will end when de-asserting the LED ON/OFF.
Figure 44.
PLC Screen, UV LED Inactivated (Off)
Figure 45.
PLC Screen, UV LED Activated (On)