TM-051 PN 35903 EC Series Models 38105, 38100, 38110
Rev 04/16/08
10
Physical
Lamp/Reflector Assembly Housing Dimensions. (approx.) 10.5" W x 9.0" D x 7.5" H.
Lamp/Reflector
Assembly
Housing Weight ......................... (approx.) 3.4 lbs.
See GENERAL specifications for further information.
Output Intensities (Typical)
WAVELENGTH
INITIAL INTENSITY
(mW/cm
2
)
UV-A * (365 nm)
400
* Intensity 4.5” from bottom edge of lamp/reflector assembly housing with the beam focused, measured with an Accu-Cal 50 UV radiometer calibrated and
traceable to NIST.
INSTALLATION AND SYSTEM INTERCONNECT
The only tool required for this procedure is
3
/
32
hex wrench which is provided with the unit.
Figure 2 - Interconnection
1 – Shutter, Optional
2 – Power Supply (8-Pin Connector)
3 – Reflector (8-Pin Connector)
4 – 8-Pin to 8-Pin Cable
5 – Cable Shutter, Optional
6 – Plug, Adapter, Optional
7 – Foot Pedal, Optional
1. Place the 400 Watt UV lamp into the lamp/reflector assembly housing. Refer to the LAMP
REPLACEMENT/INSTALLATION section of this manual.
2. A glass filter is available as an option. This filter glass reduces heat produced by lamp but will also reduce UV output
of reflector. To install the optional filter glass (sold only for the 2000 EC):
NOTICE:
It is important to wear protective gloves when installing the filter glass! Do not touch the filter with bare
fingers! Fingerprints may etch into glass and cause light transmission loss!
-
Place the reflector housing up-side down on a flat surface.
-
Loosen the four screws in the bracket that hold the reflector to the housing.
-
Slide the filter glass under the brackets and adjust it symmetrically over the reflector aperture.
-
Tighten the four screws.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com