background image

 BCD and 1 of 8 Output Voltages 

 
The

 CC-8A

 supplies a 12 Vdc BCD or 1-of-8 control voltage to external devices.  

 
The DX Engineering 

RR8

 remote 8-port RF switch requires a nominal 12 Vdc relay control 

voltage. If you are using another switch, ensure the proper control voltage is selected before you 
power-on the Control Console.  
 
The relay control voltage in BCD format is present on the 5 terminal, BCD connector corresponding 
to the front panel LED indicators as depicted in 

Table 1

. The “1” signifies the output voltage 

present between that terminal and either pin G (Ground). 
 

LED ON 

GND 

GND 

GND 

GND 

GND 

GND 

GND 

GND 

GND 

GND 

GND 

GND 

GND 

GND 

GND 

GND 

Table 1 - BCD Output Truth Table 

 
The brightness for the front panel indicator LED’s is fully adjustable by the potentiometer on the 
rear panel.  

 

The relay control voltage in 1-of-8 format is present on the 10 terminal, 1-of-8 connector, 
corresponding to the front panel LED indicator as depicted in

 Table 2

. The “1” signifies the output 

voltage present between that terminal and either pin G (Ground). 
 

LED 

ON 

GND 

GND 

GND 

GND 

GND 

GND 

GND 

GND 

GND 

GND 

GND 

GND 

GND 

GND 

GND 

GND 

Table 2 - 1-of-8 Output Truth Table 

Summary of Contents for DXE-CC-8A

Page 1: ...le DXE CC 8A DXE CC 8A INS Revision 1c DX Engineering 2017 1200 Southeast Ave Tallmadge OH 44278 USA Phone 800 777 0703 Tech Support and International 330 572 3200 Fax 330 572 3279 E mail DXEngineerin...

Page 2: ...utes to read this brief user guide and familiarize yourself with the installation operation and safety procedures We are confident that you will find this control console easy to use and that it will...

Page 3: ...ur operating position The brightness adjustment for the front antenna switch LED Light Emitting Diode indicators is also located on the rear panel The CC 8A has an attractive wear resistant laminated...

Page 4: ...he screws CCW before wire ends are inserted Do not force the screw beyond the stop Figure 3 CC 8A Rear Connectors The green connector plugs sockets on the rear of the DXE CC 8A are in two parts The to...

Page 5: ...amp Optional DXE PSW 12D1A AC Adapter 12 Volt DC 1000 mA Wall Transformer Control lines can normally use good quality CAT5e cable 4 twisted pairs of 24 AWG wire for runs up to 1000 feet Typical DX Eng...

Page 6: ...GND 0 0 0 GND 2 GND 1 0 0 GND 3 GND 0 1 0 GND 4 GND 1 1 0 GND 5 GND 0 0 1 GND 6 GND 1 0 1 GND 7 GND 0 1 1 GND 8 GND 1 1 1 GND Table 1 BCD Output Truth Table The brightness for the front panel indicat...

Page 7: ...eum products Lightning Protection As with any electrical device lightning is a concern The robust construction and sturdy parts used in the CC 8A offers a great deal of lightning and surge protection...

Page 8: ...DXEngineering com For best service please take a few minutes to review this manual before you call This unit is RoHS Reduction of Hazardous Substances compliant The components including the solder use...