background image

Rear Panel  

 
 
 
 
 
 
 
 
 
 
 
 

 

DC Input       LED Brightness Knob         J1 - 1 of  8 Connector       J2 -  BCD Connector 

 

Figure 2 - Rear Panel 

 
The 

CC-8A

 has two removable plug and socket connectors for control line connections on the rear 

panel. Connections are made with a screwdriver; no soldering is required. Do not attempt to solder 
wires to the connector, and do not over-tighten the screws. Remove 1/4 inch of insulation from each 
control wire so the screw terminals tighten on the wire and not the insulation. This will also protect 
adjacent wires from the potential of shorting together. Stranded wire should be tightly twisted or 
very lightly tinned before insertion. Open terminal slots by turning the screws CCW before wire 
ends are inserted. Do not force the screw beyond the stop.  
 
 
 
 
 

 

 
 

 
 

Figure 3 - CC-8A Rear Connectors 

 
The green connector plugs/sockets on the rear of the 

DXE-CC-8A

 are in two parts. The top 

connector part can be removed by pulling it straight off. This will allow easier wire replacement or 
servicing as needed. When pushing the connector top back in place, ensure you press straight 
inward. 
 
A Cable P-Clamp is provided to run the control cable through for strain relief. A 9-wire (including 
ground) control cable with minimum 24 AWG size conductors should provide satisfactory results 
for runs to approximately 1000 feet when used with the DX Engineering 

DXE-RR8-HP

 series 

switches or 500 feet when used with the 

DXE-RR8-SD

 switch (use 1 of 8 type connections). A 

good quality, shielded CAT5 cable such as 

DXE-CW9

 Shielded Control Wire can be used provided 

Summary of Contents for DXE-CC-8A

Page 1: ...le DXE CC 8A DXE CC 8A INS Revision 1c DX Engineering 2017 1200 Southeast Ave Tallmadge OH 44278 USA Phone 800 777 0703 Tech Support and International 330 572 3200 Fax 330 572 3279 E mail DXEngineerin...

Page 2: ...utes to read this brief user guide and familiarize yourself with the installation operation and safety procedures We are confident that you will find this control console easy to use and that it will...

Page 3: ...ur operating position The brightness adjustment for the front antenna switch LED Light Emitting Diode indicators is also located on the rear panel The CC 8A has an attractive wear resistant laminated...

Page 4: ...he screws CCW before wire ends are inserted Do not force the screw beyond the stop Figure 3 CC 8A Rear Connectors The green connector plugs sockets on the rear of the DXE CC 8A are in two parts The to...

Page 5: ...amp Optional DXE PSW 12D1A AC Adapter 12 Volt DC 1000 mA Wall Transformer Control lines can normally use good quality CAT5e cable 4 twisted pairs of 24 AWG wire for runs up to 1000 feet Typical DX Eng...

Page 6: ...GND 0 0 0 GND 2 GND 1 0 0 GND 3 GND 0 1 0 GND 4 GND 1 1 0 GND 5 GND 0 0 1 GND 6 GND 1 0 1 GND 7 GND 0 1 1 GND 8 GND 1 1 1 GND Table 1 BCD Output Truth Table The brightness for the front panel indicat...

Page 7: ...eum products Lightning Protection As with any electrical device lightning is a concern The robust construction and sturdy parts used in the CC 8A offers a great deal of lightning and surge protection...