![Dvorak SPIDER ILD01 G Service Manual Download Page 62](http://html1.mh-extra.com/html/dvorak/spider-ild01-g/spider-ild01-g_service-manual_2544108062.webp)
62
/
66
SM-1 Ev6/25062014
Default values: Recommended range:
Zero position offset
-1
-5 +5
Maximum angle
100
90 – 100
Minimum power offset
30
25-30
Zero range
2
2-4
Contra signal
4
4-6
Possible adjustments:
Zero Position Offset
-
To set an offset to the neutral (middle) position of the hydraulic servomotor.
Maximum angle
-
To set the limit (range) angle of the hydraulic servomotor –max. speed for both sides
Minimum power offset
-
To set the minimum power. When the reactions of the servo are too slow, it can be set higher.
-
Oscillation of the servo can be correct with decreasing to value 25
Zero range
-
To set the tolerance of the set point of the hydraulic servomotor. When it is 0 the motor will adjust to the
exact angle-range for the neutral is 0 so servo will oscillate. This can be resolved with increasing to value
above 2 up to 4
Contra signal
-
To set the value of the contra signal. When joystick returns to the zero position the receiver generates a
short contra (reverse) signal in the backward direction. This will stop the slow drive of the hydraulic drive.
Visible mainly in Turtle mode
Match Handset to Control Unit
-
When you select the tab “
Serial-no
” you can set the system address of the NBB control unit-receiver. Use
the serial number of the hand set-transmitter (under battery) and “
Write
” it to the NBB control unit. Use
this fntion to match the control unit with a new hand set.