background image

 

 

 

SETTINGS 

 

The GIX volumetric softener series features the Logix 760 valve. 
Thanks  to  their  user-friendly  approach,  they  can  easily  be  set. 
They  have  4  buttons  that  are  used  to  set  current  time, 
regeneration  time,  the  amount  of  salt  to  be  used  for  a 
regeneration cycle and water hardness data.  
Once  set,  the  volumetric  softener  will  count the number  of  litres 
flowing  through  it,  and  it  will  automatically  carry  out  a 
regeneration cycle when the resin is close to depletion.  
Typically, during operation, its display shows the actual time, the 
current  date,  and  the  number  of  litres  remaining  before  a 
regeneration cycle. 

During a regeneration cycle, the display shows the time needed 
before completion as well as the phase it is in. 
 
It is possible to lock the displayed information so as to avoid any 
hazardous data modification.  
 

INSTALLATION INSTRUCTIONS: 

We suggest installing the equipment: 

 

A-NON-RETURN VALVE 
B-OUTLET TAP 
C-BY-PASS TAP 
D-INLET TAP 
E-OVERFLOW PIPE 
F-UNLOADING PIPE 
 

 
 
Install on the water outlet a check valve (A) (DVGW, DIN 1988 
T2)  to  protect  the  water  softener  from  a  reverse  flow  of  hot 
water that could cause damage. 

 

 
 

Summary of Contents for GIX Series

Page 1: ...Height mm 515 540 650 Weight Kg 11 12 15 Cylinder capacity l 5 8 12 Liters of resin l 3 5 5 5 9 Nominal flow rate at 4 bar 1500 l h Room temperature Min 4 C Max 35 C Feed water temperature Min 6 C Max 25 C Pressure of feed water 0 2 0 8 MPa 2 8 bar Power supply INPUT 230V 50 60 Hz standard 120V 60 Hz optional Absorbed power 4W ...

Page 2: ...epletion Typically during operation its display shows the actual time the current date and the number of litres remaining before a regeneration cycle During a regeneration cycle the display shows the time needed before completion as well as the phase it is in It is possible to lock the displayed information so as to avoid any hazardous data modification INSTALLATION INSTRUCTIONS We suggest install...

Page 3: ...ating If possible install a pipe that keeps a few meters distance at least 3 between the outlet of the water softener and the inlet of the boiler Keep away from corrosive or acid products CONNECTION TO THE DRAIN SYSTEM A The drain pipe is not flattened or bent as water should flow without impedements THE OVERFILL PROTECTION PIPE B Insert flexible pipe in the quick joint then connect the pipe to a ...

Page 4: ...t during a regeneration cycle Such device uses salt so as to carry out resin disinfection If salt is not present the device will not start Once the regeneration cycle is over an orange led light will turn on this means that salt shall be added in brine MAINTENANCE FOR THE INSTALLER For the equipment to work in optimal conditions we suggest performing the following operations periodically Clean the...

Page 5: ...er only consists in refilling the brine periodically with sodium chloride NaCl common salt If salt is lacking the water softener will not be able to soften the water AMOUNT OF SALT GIX5V GIX8V GIX12V Salt of regeneration kg 0 6 1 1 5 Salt in the brine tank kg 10 20 25 LITRES OF SOFT WATER BASED ON WATER HARDNESS f d ppm CaCO3 20 11 200 30 16 300 40 22 400 50 28 500 60 33 600 Cyclic Capacity m 3 f ...

Reviews: