26
RMO200
Error Messages
10 Error Messages
Any operational error is indicated by a red LED and accompanied by an alarm.
Furthermore, the display indicates an error status message.
To stop the alarm buzzer, remove the status message on the display, and return
to the
Sing
menu, press the
STOP
button.
10.1 Error Message "Connection VS"
Note:
Voltage sense cables disconnection, occured during the test, will
cause an erroreous result. The display will not show this asan
error message.
10.2 Error Message "Open Connection"
Figure 10-1:
Disconnection
of a
"
Voltage
Sense
"
cable and error
message
If one of the "Voltage Sense"
cables to the test object is
disconnected, on either the
test set or the test object side
at the start of the test, the
error message "Connection
VS" is displayed.
Figure 10-2:
Disconnection of
the current
cables and error
message
If one of RMO200 current
cables ("+" or " -") to the test
object is disconnected, on
either the test set or the test
object side
at the start or
during the test, the error
message "Open
Connection" is displayed.