DutchWest 2478 Homeowner'S Installation And Operating Manual Download Page 31

31

Dutchwest

®

 Non-Catalytic Convection Heater

30002278

Dutchwest Convection Heater 

(continued)

 

Models 2478

  Ref.   Description 

2478

 

8.  Brick Support Bracket 

30004465

 

9.  Shoe Refractory 

30002101

 

  Shoe Gasket 

30002286

  10.  Lower Fireback Refractory 

30002102

 

11.  Upper Fireback Refractory 

30002212

  12.  Lower Retainer 

30002272

  13.  Right End Insulation 

30002209

  14.  Right End Refractory 

30002213

  15.  Lower Load Door Refractory 

30002222

  16.  Primary Air Flap Assembly 

30002735

  17.  Inner Top 

30002080

  18.  Fireback Retainer 

30002203

  19.  Damper 

7000954

  20.  Damper Adjuster 

7000950

  21.  Damper Crank 

7000951

  22.  Damper Operating Rod 

30002274

  23.  Ash Door 

30002091

  24.  Ash Lip 

30002204

  25.  Front Door 

30002085 

 

  Door Gasket (Front, Ash and Load Doors) 

1203589

  26.  Kaowool 

30004711

  27.  Inner Door 

30004710

  28.  Wood Handle w/Lifter 

30002787

  29.  Load Door (to June 2005) 

30002084* 

 

 

  Load Door II (replaces above) 

30002439** 

 

 

  ** When using to replace original door, use new refractory and load door insulation

  30.  Grate 

30002092

  31.  Damper Handle 

5004265

  32.  Top 

30002079

  33.  Flue Collar 

7000969

 

  Flue Collar Gasket 

1203591

  34.  Outer Back 

30002226

  35.  Ash Pan 

7000G69

  36.  Ashdoor Handle 

5004237

  37.  Glass 

30002097

 

  Glass Gasket 

1203560

  38.  Glass Clips 

30002146

  39.  Leg 

30002086

  40.  Pawl Assembly 3/4” Short Adjuster 

30002362

  41.  Front & Side Door Handle 

5004245

  42.  Bottom Heat Shield 

30002280

  43.  Primary Air Manifold 

30002089

  44.  Front 

30002081

  45.  Andirons (2) 

7001117

  46.  Bracket, Rheostat 

30002216

  47.  Pawl Assembly 3/4” short adj. 

30002362

  48.  Fountain HS 

30004572

  49.  Left Delector HS 

30004568

  50.  Right Delector HS 

30004569

Summary of Contents for 2478

Page 1: ...this heater is not properly installed operated and maintained a house ire may result For safety follow all installation operation and maintenance directions Contact local building oficials about rest...

Page 2: ...to cause cancer birth de fects and other reproductive harm California Health Safety Code Sec 25249 6 Table of Contents Speciications 3 Installation 4 Clearances 10 Assembly 16 Operation 18 Maintenanc...

Page 3: ...d or if you live in a more severe or more temper ate climate these igures may not apply Since so many variables affect performance consult your Dutchwest Authorized Dealer to determine realistic expec...

Page 4: ...must be connected to 1 a chimney complying with the requirements for Type HT chimneys in the standard for Chimneys Fac tory Built Residential Type and Building Heating Appli ance UL 103 or 2 a code a...

Page 5: ...himney Connector The chimney connector is the single wall pipe or listed and approved double wall pipe that connects the stove to the chimney The chimney itself is a masonry or prefabricated structure...

Page 6: ...telescoping joints with at least three sheet metal screws 3 Secure the chimney connector to the chimney In structions for various installations follow below 4 Conirm that the installed stove and chim...

Page 7: ...rises from the stove turns ninety degrees and goes back into the ireplace chimney The liner of the ireplace chimney should extend at least to the point at which the chimney connector enters the chimne...

Page 8: ...all is cut away a sufi cient distance from the single wall connector to provide the required 12 305 mm clearance for the connector Any material used to close up the opening must be non combustible The...

Page 9: ...rial with an R value of at least 0 744 Refer to How to Deter mine if Alternate Floor Protection Materials are Accept able section The loor protector may be covered with a decorative noncombustible mat...

Page 10: ...installations must include the bottom heat shield The loor protector must also meet standard requirements for freestanding installations Floor Protection for Fireplace Installations with Standard Leg...

Page 11: ...furnish ings and other combustible materials away from the stove as well In general a distance of 48 1220 mm must be maintained between the stove and moveable combustible items such as drying clothes...

Page 12: ...the Stove and Chimney Connector Clearance Chart that follows For example the letter A gives the minimum side clear ance for installations in which the stove is not equipped with any heat shield and th...

Page 13: ...P 7 heat shield 432 mm 381 mm 191 mm 178 mm 368 mm 178 mm Double wall connector Chimney Connector Clearance Single wall connector 20 14 No connector heat shield 508 mm 356 mm Single wall2 connector 10...

Page 14: ...wall protector A B C E D F C F Chimney Connector Side Rear Corner Side Rear Corner Listed Approved A 30 B 13 C 18 D 21 E 12 F 18 Double wall with 762 mm 330 mm 470 mm 533 mm 318 mm 457 mm lue collar...

Page 15: ...er Model 2478 48 1220 mm 60 1525 mm Spaced 1 25 mm from Floor ST802 Fig 17 Sidewall protection 60 1525 mm 48 1220 mm Spaced 1 25 mm from Floor ST803 Fig 18 Corner wall protection Wall Shields Meet at...

Page 16: ...parts or using damaged parts A Bottom Heat Shield is required in many instal lations Refer to the loor protection information found in the Installation Section of this manual Attach the Legs and Heat...

Page 17: ...owly to ensure the loor is not scratched Retighten all leg fastening hardware ST816 Fig 21 Reposition stove so one rear leg can be attached Rheostat Knob Rheostat Snapstat Pan Head Screws Fig 23 Fan i...

Page 18: ...stove Fig 24 The lever operates two internal shut ters Opening the inlet shutters provides air for primary combustion To open the shutters turn the lever clockwise The shutters are all the way open wh...

Page 19: ...quickly resulting in short burn time and dimin ished stove performance If you must burn it mix it in with greener wood to slow the burn Store your irewood under cover to keep it dry Even for short te...

Page 20: ...empt to increase the iring rate of your heater by altering the air control adjustment range outlined in these directions In some newer homes that are well insulated and weather tight poor draft may re...

Page 21: ...T THE FIRE DO NOT BURN GARBAGE OR FLAM MABLE FLUIDS SUCH AS GASOLINE NAPTHA OR ENGINE OIL Also never use gasoline type lantern fuel kerosene charcoal lighter luid or similar liquids to start or freshe...

Page 22: ...on a noncombustible surface in a metal container with a tight itting lid ST438 ST805 Fig 29 Check the ash compartment before reloading the stove Safe Ash Handling Ashes may contain hot coals and must...

Page 23: ...procedure Fig 31 1 Loosen the small locking nut with an open end wrench 2 Use the allen wrench included with the stove to turn the striker screw clockwise one quarter turn and close the door to test...

Page 24: ...loosen and then remove the two 2 nuts on the threaded rods that secure the top plate to the inner top of the stove 2 Remove the top plate and open the damper 3 Loosen the adjusting bolt s lock nut Fi...

Page 25: ...stove cool completely before you inspect the chimney Use a lash light and mirror to sight up the lue through the chimney clean out door or chimney connector inspection tee If no inspection access is...

Page 26: ...tor and the elbows Clean the system if nec essary ANNUAL SPRING CLEANING Disassemble the chimney connector and take it outdoors for inspection and cleaning Replace weak sections of connector Inspect t...

Page 27: ...m the high lue temperatures Because the insulation is less dense than masonry the inner steel liner warms up more quickly than a masonry chimney this makes the steel chimney support a good draft more...

Page 28: ...re All of the installation characteristics that adversely affect chimney draft also promote creosote condensation Consequently you can minimize creosote accumulation with an effective chim ney design...

Page 29: ...Conclusion Woodburning is more an art than a science Art in cludes technique and since installations homes and fuel vary the stove operator must also vary technique mostly timing to achieve satisfyin...

Page 30: ...he right to make changes in design materials speciications prices and discontinue colors and products at any time without notice Dutchwest Convection Heater Model 2478 Ref Description 2478 1 Bottom 30...

Page 31: ...85 Door Gasket Front Ash and Load Doors 1203589 26 Kaowool 30004711 27 Inner Door 30004710 28 Wood Handle w Lifter 30002787 29 Load Door to June 2005 30002084 Load Door II replaces above 30002439 When...

Page 32: ...r any fuel not recommended in the Owners Guide 4 This warranty does not cover a stove repaired by someone other than a Dutchwest Authorized Dealer 5 Damage to the unit while in transit is not covered...

Reviews: